Kenmore 625.3888 Water System User Manual


 
SECTION1 WATER SOFTENER START UP
C. PROGRAM THE TIMER
_SET WATER HARDNESS NUMBER
Press the SELECT button once to display 25 (de-
fault) and HARDNESS setting screen.
The grains per gallon Hardness:
(gpg) hardness of your _ Grains
water supply is on your
water analysis report. Be
sure to write down water Av CHANGE SELECT
test results on page A,
and on instruction decal located under the salt cov-
er, for future reference.
If your water supply contains iron, compensate for
it by adding to the water hardness number. For ex-
ample, assume your water is 20 gpg hard and contains 2
ppm iron. Add 5 to the hardness number for each 1 ppm
of iron. In this example, you would use 30for your hard-
ness number.
20 gpg hardness
2 ppmironx 5 = 10 +10
(times) 30 HARDNESS NUMBER
Press the UP / DOWN buttons to set your water
hardness number in the display. The DOWN button
moves the display to 1. The UP button moves the
display to the highest setting (see maximum setting
Note:
Each press of the UP / DOWN button changes the
hardness setting by 1.
_SET RECHARGE (REGENERATION) TIME
Press the SELECT button to display 2:00 AM (de-
fault) and RECHARGE TIME setting screen.
At the 2:00 AM recharge RechargeTime:
time setting, the softener _ AM
begins regeneration (see
pages 2-3 and 2-4) at 2:00
AM and lasts appoxi- Av CHANGE SELECT
mately 2-1/2 hours. This
is a good time in most households because water is
not being used (see Automatic Bypass, page 2-6). If
a different recharge time setting would be better for
your household, do the following.
Press the UP / DOWN buttons to set the desired
recharge starting hour. Be sure to observe the AM-
PM as you did when setting the present time of day.
Press the SELECT button once again, to com-
plete initial programming.
l! 5:39 PM[
Recharge Tonight
[ ]1More
Water Flow
Normal Operating Screen
has several useful items
that can be viewed at a
glance. The black bars on
the left column display
the amount of salt in the
[] 5:39 PM I
Recharge Tonight I
]]More
Water Flow
storage tank. The present time is shown in the up-
per right hand corner. Options are shown in the top
center of the display. If the unit is going to recharge
tonight or is in a recharge, this is shown. By press-
ing the Up/X arrow displays the "More" screen.
"More" Screen shows the PCaterUsed'ibday:
water used today, average
daily use, average pounds
of salt used per recharge
0 Gallons
Avg Daily Use:
0 Gallons
Avg Salt/Rchg:
0.0 Pounds
R_,charg,, Count
0
and recharge count. If the recharge count is reset to
zero, the average pounds of salt per recharge is reset
also.
PROGRAM MEMORY If electrical power to the
softener goes off, the time display is blank but the
face plate timer keeps the correct time for about 72
hours. When electrical power comes on again, you
have to reset the present time only if the Set Present
Time display is showing. The HARDNESS and RE-
CHARGE TIME never require resetting unless a
change is desired. Even if the timer is incorrect after
a long power outage, the softener works as it should
to keep your water soft. However, regenerations
may occur at the wrong time of day until you reset
the timer to the correct time of day.
IF YOU NEED HELP PROGRAMMING THE TIMER, CALL TOLL FREE,
NUM BER 1- 800- 426- 9345.
SEE SECTION 2 FOR OTHER FACE PLATE TIMER FEATURES.