Ingersoll-Rand 6544X-X Water Pump User Manual


 
OPERATOR’S MANUAL 6544X-X
6546X-X
INGERSOLL RAND COMPANY LTD
P.O. BOX 151
ONE ARO CENTER
BRYAN, OHIO 43506-0151
(800) 276-4658
FAX (800) 266-7016
© 2007 CCN 81582769
RELEASED: 2-26-82
REVISED: 11-28-07
(REV. U)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
4-1/4” AIR MOTORS
6544X-X (4” STROKE) and 6546X-X (6” STROKE)
Also covers 61268 service kits
INCLUDING: SERVICE KITS, TROUBLESHOOTING, PARTS LIST,
DISASSEMBLY & REASSEMBLY.
Figure 1
SERVICE KITS
Use only genuine ARO® replacement parts to assure com-
patible pressure rating and longest service life.
61268 for general repair of all 4-1/4” air motors.
GENERAL DESCRIPTION
WARNING
DO NOT EXCEED MAXIMUM OPERATING
PRESSURE AS INDICATED ON PUMP MODEL PLATE.
WARNING
REFER TO GENERAL INFORMATION SHEET
FOR ADDITIONAL SAFETY PRECAUTIONS AND IMPOR-
TANT INFORMATION.
This manual only covers the air motor section. It is one of
four documents which support an ARO pump. Replace-
ment copies of these forms are available upon request.
650XXX-X Pump Model Operator’s Manual.
General Information for Air Operated or Hydraulically
Operated Pumps.
Lower Pump End Operator’s Manual.
Air or Hydraulic Motor Operator’s Manual.
The 4-1/4” air motor is a general purpose power unit and
is used with many 2-ball, 4-ball and chop check pumps. It
utilizes tie rod type construction for easy breakdown and
it connects to the various lower ends via tie rods for easy
operation. Consult pump model operator’s manual for
speci c instructions. It is recommended that a mu er be
connected to the exhaust port to reduce noise to accept-
able OSHA standards.
Filtered and oiled air will allow the air motor to operate
more e ciently and yield a longer life to operating parts
and mechanisms. A filter capable of filtering particles
larger than 50 microns should be used with an oiler. Keep
the oiler supplied with a good grade of S.A.E. no. 90W
non-detergent gear oil, set at a rate not to exceed 1 or 2
drops per minute.
NOTICE: Do not operate the air motor above the recom-
mended air pressure of 150 p.s.i. (10.3 bar) or 75 cycles
per minute. The air motor may be rated di erently in the
next assembly. Check the pump model plate.
THIS MANUAL COVERS THE FOLLOWING MODELS
MODEL
65440 65442-B 65444-2-B 65462
65441-B 65444-B 65445-B 65465-B
Also covers obsolete and cancelled models: 61777, 65420-1, 65443-B, 65443-2-B, 65444-1B, 65465-1-B and 65466.
MAINTENANCE
The air / hydraulic motor is completely separate from the
lower pump end. This helps to keep the motor from being
contaminated by the material being pumped. Periodically,
ush entire pump system with a solvent that is compatible
with the material being pumped.
Keep solvent cup  lled with this compatible solvent. This will
keep material from drying on the piston rod, which would
drag thru the packings, ruin them and eventually scour the
piston rod.
Provide a clean work surface to protect sensitive internal
moving parts from contamination from dirt and foreign mat-
ter during disassembly and reassembly.
Before reassembling, lubricate parts as required. When as-
sembling “O” rings, or parts adjacent to “O” rings, exercise
care to prevent damage to “O” rings and “O” ring groove sur-
face.