OPERATOR’S MANUAL
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
650240-X-B
SERVICE KITS
x Use only genuine ARO replacement parts to assure compatible
pressure rating and longest service life.
x 61268
for repair of air motor section.
x 637058
for repair of lower pump section (Leather).
x 637059
for repair of lower pump section (PTFE).
PUMP SYSTEM DATA
Model Series 650239-1--B & 650240....................
System Type Air operated, 2-ball double...................
acting cart mounted pump
Basic Pump 65814-X-C....................
Ratio 9:1.........................
Air Motor 65445-B......................
Motor Repair Kit 61268................
Motor Diameter 4-1/4” (10.8 cm)................
Stroke 4” (10.2 cm).......................
Air Inlet 1/2” -14 N.P.T.F.- 1(female)......................
Lower Pump End Series 65965-X..........
Lower Pump Repair Kit 63705X...........
Material Outlet 3/4” -14 N.P.T.F.- 1(female)................
OPERATING AND SAFETY PRECAUTIONS
WARNING
READ THE GENERAL INFORMATION MANUAL
INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS
AND OTHER IMPORTANT INFORMATION.
WARNING
DO NOTEXCEEDMAXIMUM OPERATINGPRES-
SURE OF 1350 P.S.I. (93 BAR) AT 150 P.S.I. (10.3 BAR) AIR IN-
LET PRESSURE.
WARNING
REFER TOTHE PUMP MANUAL FORADDITION-
ALOPERATINGANDSAFETYPRECAUTIONSANDOTHERIM-
PORTANT INFORMATION.
IMPORT
ANT
This is one of the eight documents which support the pump. Re-
placement copies of these forms are available upon request.
= 650239 MODEL OPERATOR’S MANUAL
- GENERAL INFORMATION - PUMPING SYSTEMS
(PN 97999-636)
- 67075--X--B CARTS MANUAL (PN 97999-1018)
- 6544X-X AIR MOTOR OPERATOR’S MANUAL (PN 97999-064)
- 65184X-X FOLLOWER PLATE OPERATOR’S MANUAL (PN
97999-605)
MODEL DESCRIPTION CHART
PUMP (1) PUMP LOWER
PACKAGE
MODEL NO. PUMP END
650239--X--B 65814-X--C 65965--X
650240--X--B 65814-X--C 65965--X
AIR AND LUBE REQUIREMENTS
x Excessiveairpressurewillshortenthelifeofthepump.Donotoper-
ate pump above recommended maximum air pressure.
Formaximumoperatingefficiency,thefollowingairsupplyspecifica-
tion should be maintained to this pump:
x AIR PRESSURE - Refer to maximumpressure note in Operat-
ing Precautions.
x AIR FILTRATION - 50 micron
x LUBRICATED AIR SUPPLY
x AIR INLET SIZE - 1/2” N.P.T.F. - 1
x Filtered and oiled air will allow the pump to operate more efficiently
and yield a longer life to operating parts and mechanisms.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276
FAX(800) 892-6276
© 2011 CCN 15330053
www.ingersollrandproducts.com
650239--X--B
RELEASED: 1-13-10
(REV. 01)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
650239--X--B & 650240--X--B
ALSO INCLUDE MANUALS: 67075--X--B CART (PN 97999-1018), 6544X-X AIR MOTOR (97999-064), R272X1-XXX REGULATOR
(100400-006),, 65184X-X FOLLOWERPLATE (97999-605) & S-636 GENERAL INFORMATION(PN 97999-636).
(4-1/4” AIR MOTOR - 9:1 RATIO)
PUMP AND CART ASSEMBLY