Honeywell W8635A Water Heater User Manual


 
W8635A EQUIPMENT INTERFACE MODULE
69-133922
Fig. 2. Mounting W8635A
Equipment Interface Module.
4.
Position the W8635A on the wall or on the cold air
return.
5.
Level the W8635A for appearance only; the device
functions properly even when not level.
6.
Use a pencil to mark the position of the mounting
holes on the wall or cold air return.
7.
Remove the W8635A from the wall or cold air
return and drill 3/16 in. holes in the wall (if drywall)
where marked. For firmer materials such as plaster
or wood, drill 7/32 in. holes.
8.
When mounting on the cold air return, drill a pilot
hole where marked.
9.
Gently tap the anchors (provided) into the holes
until flush with the wall.
10.
Reposition the W8635A over the holes.
11.
Loosely insert the screws into the holes and tighten
each screw.
WIRING
All wiring must comply with local electrical codes and
ordinances. See Fig. 4 through 6 wiring diagrams for
specific equipment applications. Refer to Table 2 for
terminal designations.
CAUTION
Voltage Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power before beginning installation.
1.
Loosen the terminal screws on the W8635A and
connect the system wires. See Fig. 3.
2.
Securely tighten each terminal screw.
Fig. 3. Wiring the W8635A terminals.
Table 2. Terminal Designations.
Fig. 4. 2H/2C single transformer.
Y2
W
2
Y1
G
W
1
C
R
R
H
R
C
1
2
3
MOUNTING
HOLES (2)
MOUNTING
SCREWS (2)
W8635
WALL
M16636
W8635A
Terminal
Designations Function
1 To Communicating Thermostat
Terminal 1
2 To Communicating Thermostat
Terminal 2
3 To Communicating Thermostat
Terminal 3
R 24 Vac System Transformer
Rh 24 Vac Heating Transformer
Rc 24 Vac Cooling Transformer
C 24 Vac Transformer Common
GFan Relay
W1 Stage 1 Heat Relay
W2 Stage 2 Heat Relay
Y1 Stage 1 Cool Relay
Y2 Stage 2 Cool Relay
Green LED Indicates Data Communication
FOR WRAPAROUND
CONNECTION
STRIP 7/16 IN. (11 MM)
FOR STRAIGHT
CONNECTION
STRIP 5/16 IN. (8 MM)
M16639
W8635
L1
(HOT)
L2
COOL 1
RELAY
HEAT 2
RELAY
FAN
RELAY
OT
OT
2
1
3
FACTORY INSTALLER JUMPERS.
M13429
C7089B
OUTDOOR
TEMPERATURE
SENSOR
1
T8635L
HEAT 1
RELAY
W8635A
C
R
R
H
R
C
1
2
3
Y2
W2
Y1
G
W1
COOL 2
RELAY
1
SYSTEM
TRANSFORMER