INSTALLATION INSTRUCTIONS
69-1200-2
W8600F Air Cleaner Monitor
APPLICATION
The W8600F Air Cleaner Monitor is an option available
for use with the F50F and F52F Honeywell Electronic Air
Cleaners (EAC). The series two F50F and F52F require
a solid state power supply that is compatible with the
W8600F driver board. Any series one F50E, F or F52F
can be upgraded to use the W8600F when the power
supply is replaced and the driver board (included in
W8600F kit) is installed.
The W8600F function indicator panel has four liquid
crystal display (LCD) arrowheads that point to ON,
BATTERY, SERVICE or FAULT. See Fig. 1. The
arrowheads darken to indicate the existing EAC
condition. See Table 1.
INSTALLATION
When Installing this Product..
1. Read these instructions carefully. Failure to follow
theinstructions coulddamage theproduct orcause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product tomake sure the product issuitable for
your application
3. Installer must be a trained, experienced service
technician.
4. After completing the installation, use these instruc-
tions to check out the product operation.
Location
The styling of the W8600F is designed to blend with the
latest T8600 family of Honeywell Chronotherm¨ IV
Deluxe Programmable Thermostats. A special mounting
template is included for mounting next to the T8600. The
W8600F can also be mounted at any other convenient
location in the living area or equipment room. See Fig. 2.
NOTE: The W8600F sharesno commonelectrical con-
nections with the thermostat.
Fig. 1. W8600F Air Cleaner Monitor features.
a
The reset button is located on the bottom of W8600F.
Aftertheprefilters andcells arecleaned and reinstalled,
press this button to turn off the SERVICE indicator and
reset the wash frequency timer.
Table 1. Description of W8600F Function Indicator
Panel.
Indicators Condition
ON EACispoweredandsystemblower is
running.
BATTERY Battery that maintains W8600F
memory is low andneeds to be
replaced.
SERVICE EAC prefilter and cells need to be
washed
a
.
FAULT •Shorting of collectorplates.
•Continuous ionizer or collector plate
arcing.
•Power supply failure.
•Excessive current.
•Major reduction in high voltage.
•EAC prefilter and cells are past
SERVICE level of dirt and need to be
washed immediately.
Calla servicetechnician.
ON
BATTERY
SERVICE
FAULT
Air Cleaner Monitor
FUNCTION
INDICATOR
PANEL
LCD
RESET BUTTO
N
M11965