Honeywell H6062A1000 Dehumidifier User Manual


 
HumidiPRO™ Digital Humidity Control
H6062A1000
SPECIFICATION DATA
33-00003-01
Specifications
Part Number: H6062A1000
Supply Voltage: 18 to 30 VAC (50/60 Hz)
Amps: 0.1 A, 2 VA
Dimensions (See Fig. 1):
Width: 3.4 in.
Height: 1.27 in.
Length: 4.5 in.
Weight: 0.5 lbs
Shipping Dimensions:
Width: 4.05 in.
Height: 2.55 in.
Length: 5.88 in.
Weight: 0.67 lbs
Humidity Ranges:
Humidify Control Range:
• 20 - 60 % (Automatic mode)
• 10 - 90 % (Manual mode)
Dehumidify Control Range:
• 40 - 80 % (Automatic mode)
• 10 - 90 % (Manual mode)
Operating Ambient Temperature
• 32 to 120 °F (0 to 48.9 °C)
Operating Relative Humidity
• 5to95%,non-condensing
Relative Humidity Accuracy: +/- 5 % RH
For more information call 1-800-468-1502 or visit our
website at customer.honeywell.com.
Application and Benefits
HumidiPRO offers homeowners convenience and control with
automatic and manual control options as well as optional
advanced features such as expandable range stops and
dehumidification.
HumidiPRO automatically adjusts humidity to protect
windows from condensation in cold weather and can shut off
humidification based on a preset outdoor high temperature limit
(up to 90 °F). The homeowner can set HumidiPRO once at the
beginning of a season and forget it. If needed, the homeowner
can use the humidity boost feature to temporarily raise the
humidity by 5% or 10%.
Fig. 1. Dimensions in inches (mm).
M34947
1-17/64
(33)
4-1/2 (114)
3-13/32
(86)
1-17/64
(32)
Outdoor Temp
-10°F 0°F 10°F 20°F 30°F 40°F
Frost Index
1 10 10 10 10 11 11 17 17 25 25 35 36
2 10 10 10 10 15 15 21 21 29 29 35 39
3 10 10 14 14 19 19 26 26 34 34 35 46
4 15 15 19 19 25 25 32 32 35 39 35 52
5 21 21 26 26 32 32 35 38 35 48 35 58
6 29 29 34 34 35 39 35 48 35 56 35 60
7 35 39 35 46 35 52 35 58 35 60 35 60
8* 35 56 35 60 35 60 35 60 35 60 35 60
9 35 60 35 60 35 60 35 60 35 60 35 60
10 35 60 35 60 35 60 35 60 35 60 35 60
*Black Numbers show highest humidity allowed when Default RH% (35%) is Selected.
Note: Smaller grey numbers show highest humidity allowed when Maximum RH% (60%) is
selected.
Honeywell HumidPRO
TM
Frost Index
The table below shows the levels of humidity HumidiPRO delivers
based on the outdoor temperature and window protection settings.
Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
Model(s) Qty.
H6062A1000
Approval
Service
Tag. No.