197
!
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system
installation information.
Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
GSS Series
GSS
GSS Series
Global Safety Switch
FEATURES
EN 50041 and EN 50047 mounting and
characteristics
Designed to IEC electrical standard for
world-wide use in guarding applications
Positive opening operation of NC
(Normally Closed) contacts conforming
to IEC /EN 60947-5-1-3
Available with a wide range of positive
opening contacts
Rugged housing (Zinc Die-cast)
Tamper resistant design uses TORX®
head security screw
Full range of actuator heads and levers
suitable for safety applications
Sealing up to IP 67, NEMA 1, 4, 12 & 13
Snap action and slow action basic
switches
International conduit sizes
Galvanically isolated contacts
UL listed; CSA and CE certified, BG
approved
Red body colour for easy safety
recognition
BENEFITS
Standard mounting and characteristics
Globally available and accepted
Welded NC contacts will separate vital
security in safety applications
Range of actuation methods for
detecting safety conditions in guarding
and machine status applications
Wiring and body flexibility
Suitable for inductive switching and
safety relay interfaces
Signalling and power/safety circuits may
be different polarities or voltages
Immediately recognisable in the
application as a safety component
GSS Series products may be used alone as Category 1 per EN 954-1 safety compo-
nent. In conjunction with other safety switches and our complete range of safety
control modules, it is possible to construct comprehensive protection schemes
with Category 2, 3 or 4 compliance per EN 954-1.
Honeywells design experience has resulted in a brand new patented concept in
safety switching techniques. The sequential safety switch incorporates positive
opening on the downward stroke of each NC sequence point. This allows the user to
have both a warning signal and a stop signal. With this information a door can be
closed before it stops a machine or settings adjusted to stop excessive movement
thus avoiding down time.
LOW ENERGY SWITCHING
In todays demanding age of low energy controls, electromechanical switches are
frequently used to interface directly with safety relays, PLCs and other low energy
devices. To accommodate this requirement GSS offers gold plated contact versions
of the standard basic switch. This improves reliability of switching at low currents
and voltages, by protecting the contact surfaces from contamination during opera-
tion or storage prior to use.
Standard silver contacts have a disadvantage in that the contact surface may tar-
nish under certain environmental conditions e.g. in the presence of moisture.
Low energy basic switches are rated as follows:
Operating Voltage U
e
1 to 50 Vac or Vdc
Operating Current I
e
1 µA to 100 mA