2. Location
8
2-1 Indoor unit
2-2 Outdoor unit
WARNING:
Maintain the required space around the
appliance to prevent overheat.
The area for installation of the appliance should not be in an area
with the following:
Direct sunlight
Heat resource
Inflammable gas
Thick oil fog
The appliance should be installed in an area,
Where the inside space can be evenly conditioned, or
Which is strong enough for the appliance, or,
Having the shortest distance for the copper tubes and water
drain hose, and
Having desired space around the appliance for maintenance
and ventilation.
Min. 5cm
Min. 5cm
Min. 5cm
Tube arrangement
L H Add. Refrigerant Provided Tube(M)
(g/m)
15 7 25 4
L: Maximum length of the tube connecting the indoor unit and the
outdoor unit.
H: The height difference between the indoor unit and the outdoor
unit.
Tube length(L)
Height difference(H)
Indoor unit
Outdoor
unit
If the length of the tube is between 7.5m to 15m(maximum
length), an additional 25g/m of refrigerant should be added .
Additional compressor oil must not be added.
The indoor unit should not be
installed below a height of 1.8m.
The outdoor unit should be installed away from the following:
Heat source and fan exhausting ;
Director sunlight;
The outdoor unit should be installed in an area with,
Cool temperature;
Good ventilation;
Desired space for air inlet, outlet and maintenance
Air inlet
Min. 5cm
Min. 10cm
Min. 40cm
Min.10cm
Air inlet
Ground
Valve side
Min. 25cm
Top obstacle
Air outlet
Air outlet
Blockage
2
Strong base (10x40cm concrete or alike). The appliance
should be placed not less than 10cm high.
Fix the base with anchor bolts to reduce vibration and noise.
Air inlet
Concrete or alike
Anchor bolts(4)
Min. 10cm
About 10cm
Abo
ut 40cm
20
CAUTION:
Appendix: Installation