Heath Zenith SL-5408 Home Safety Product User Manual


 
3
595-5292-18
Bottom of Sensor
ON-TIME
10 5 1 TEST
MIN MAX
SENS
TEST AND ADJUSTMENT
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
Turn on the circuit breaker and light switch.
Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.
Motion
Motion
The detector is most sensitive to motion across its field
of view.
Maximum Range Maximum
Coverage Angle
Avoid aiming the control at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
60 ft.
(18.3 m)
8 ft.
(2.4 m)
110°
Least Sensitive Most Sensitive
Sensor
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
Adjust the SENSITIVITY as
needed. Too much sensitivity
may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you
want the lights to stay on after motion is detected (1,
5, or 10 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 110°
Electrical Load. . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).