INSTALLATION
For easy installation, select an existing light operated by
a wall switch for replacement.
For best performance, mount the fixture about
8 feet (2.4 m) above the ground.
WIRE THE LIGHT CONTROL.
For eave mount only:
Wall MountEave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Align the Light Control cover plate and the junction
box holes. Secure with the mounting screws.
If not installed on a weatherproof box or if an
adaptor plate (not included) was used, caulk the
wall plate and mounting surface with silicone.
MOUNT THE LIGHT CONTROL.
Rotate the sensor head towards the clamp screw
joint.
Then rotate the sensor head clockwise 180° so the
controls face down.
Control Switch
Joint Clamp
Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
Keep lamps at
least 1" (25 mm)
from the sensor.
Avoid water damage and
electrical shock - keep lamp
holders below horizontal.
Lock nuts
Black to
Black
White to
White
Gasket
Drill the holes needed to
mount the backplate to
the junction box.
Turn power off at the fuse or circuit breaker.
Remove the existing light fixture.
Route the Light Control's wires through the large
gasket hole.
Connect the junction box wires to the Light Control
wires. Twist together and secure with a wire
connector.