Heath Zenith PF-4151-AZ Home Safety Product User Manual


 
© 2007 HeathCo LLC 598-1166-04
MANUAL MODE
... back on.
1 Second
OFF then...
OPERATION
* resets to Auto Mode at dawn.
TEST
TEST 1 5 10 MIN
AUTO
TEST 1 5 10 MIN
DualBrite
®
Motion Sensing
Coach Light
Set the ON-TIME switch on
the bottom of the cover plate
to TEST and the DualBrite
®
switch OFF.
Set ON-TIME switch to
1, 5, or 10 minutes.
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10 Min x
Manual
To Dawn* x
Accent
3, 6 Hr, to Dawn x
Note: When first turned on wait about 1
1
/
2
minutes for the circuitry to calibrate.
Before installation, record the model number
from back of fixture below. Attach receipt in
case of possible warranty issues.
Items Models
231896 PF-4125-AZ
253383 PF-4129-AZ
007677 PF-4144-AZ
017726 PF-4144-NB
182143 PF-4151-AZ
063285 PF-4152-BK
253381 PF-4156-AZ
012043 PF-4166-PB
021746 PF-4166-SA
066640 PF-4180-PB
Questions or problems? Before returning
to your retailer, refer to the troubleshooting
guide in this manual or call our technical ser-
vice department at 1-800-858-8501 (English
speaking only), 7:30 am to 4:30 pm, CST,
Monday – Friday.
Features
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight
hours.
Package Contents
• Lantern
• Easy to use Universal Mounting Bracket
• Mounting Hardware
• Wire Connectors
• Some Models Include an Optional Decora
-
tive Tail Assembly
Requirements
• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control
must be wired through a switch.
Some electrical codes require installa-
tion by a qualified electrician.
Meets the ENERGY STAR
®
guidelines when DualBrite
®
function is off.