TESTING
Turn on the circuit breaker and light
switch.
The detector is less sensitive to motion
directly towards it and more sensitive to
across motion.
Sensor
Motion
Least Sensitive Most Sensitive
Walk through the coverage area noting
where you are when the lights turn on.
If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
Set the amount of time after dusk you want
the lights on accent level.
SPECIFICATIONS
Range . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature].
Sensing Angle . . . . Up to 180°
Electrical Load . . . . See rating on fixture for
maximum wattage.
Sensor Capacity . . Up to 360 Watt (3.0 A.)
Maximum
Power
Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . 1, 5, 10 minutes
DualBrite
®
timer . . 3, 6 hrs, Dusk-to-Dawn
DESA Specialty Products reserves the right to
discontinue products and to change specifica-
tions at any time without incurring any obliga-
tion to incorporate new features in products
previously sold.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on, wait 1
1
/
2
minutes.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as heating vents and air condition-
ers. These heat sources could cause false
triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects
reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
30 ft.
(9.1 m)
Maximum Range Maximum
Coverage Angle
180°
Motion
Switch the on-time to TEST position and
DualBrite
®
switch to the OFF position.
6 ft.
(1.8 m)