Graco 425 Heat Pump User Manual


 
Stationary Units
Part No. Pump Type Hose Kit Cover Follow Plate
225014 50:1 Fire-Ball 300 120 lb X X X
223108 50:1 Fire-Ball 425 120 lb X X X
244635 75:1 Fire-Ball 425 120 lb X X X
225016 50:1 Fire-Ball 300 400 lb X X X
225781 50:1 Fire-Ball 425 400 lb X X X
244636 75:1 Fire-Ball 425 400 lb X X X
Mobile Units
Part No. Pump Type Hose Kit Cover Follow Plate
Hold-down
Kit
222085 50:1 Fire-Ball 300 120 lb X X X X
223107 50:1 Fire-Ball 425 120 lb X X X X
243817 75:1 Fire-Ball 425 120 lb X X X X
222071 50:1 Fire-Ball 300 400 lb X X X X
222075 50:1 Fire-Ball 425 400 lb X X X X
243818 75:1 Fire-Ball 425 400 lb X X X X
Instructions – Parts List
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1988, Graco Inc. is registered to I.S. EN ISO 9001
Fire-Ball
R
300 and 425
Grease Pumps
307880K
Important Safety Instructions.
Read all warnings and instructions in this manual.
Save these instructions.
WARNING
These systems are designed to be used only in
pumping non-corrosive and non-abrasive lubricants.
Any other use of the system can cause unsafe op-
erating conditions and result in component rupture,
fire, or explosion, which can cause serious bodily
injury, including fluid injection.
50:1 Ratio Fire-Ball 300 Pumps: 5000 psi (35 MPa, 350 bar) Maximum Working Pressure
50:1 Ratio Fire-Ball 425 Pumps: 4000 psi (28 MPa, 276 bar) Maximum Working Pressure
75:1 Ratio Fire-Ball 425 Pumps: 4000 psi (28 MPa, 276 bar) Maximum Working Pressure
Stationary installations and mobile units for pumping non-corrosive and
non-abrasive lubricants.
Parts