Technical Data
Technical Data
Husky 2200 Diaphragm Pump
US
Metric
Maximum fluid working pressure
125 psi 0.86 MPa, 8.6 b
ar
Air pressure
operating range
20 to 125 psi 0.14 to 0.86 M
Pa, 1.4 to 8.6 bar
Air inlet siz
e
3/4 in. npt(f)
Air exhaust s
ize
1 in. npt(f)
Fluid inlet and outlet size (ANSI/DIN
flange)
2in 50mm
Maximum suction lift (reduced
if balls don’t seat well due to
damaged balls or seats, lightweight
balls, or extreme speed of cycling)
Wet: 31 ft
Dry: 16 ft
Wet: 9.4 m
Dry: 4.9 m
Maximum size pumpable solids 1/4 in. 6.3 mm
Minimum ambient air temperature
for operation and storage.
NOTE: Exposure to extreme low
temperatures may result in damage
to plastic parts.
32° F 0° C
Air consumption
Standa
rd diaphragms
70 scfm
at 70 psi; 100 gpm
2.0 m
3
/min at 0.48 MPa, 4.8
bar, 379 lpm
Overmo
lded diaphragms
75 scfm
at 70 psi, 100 gpm
2.1 m
3
/min at 0.48 MPa, 4.8
bar, 379 lpm
Maximum air consumption
Stand
ard diaphragms
140 sc
fm
4.0 m
3
/min
Overm
olded diaphragms
157 sc
fm
4.4 m
3
/min
Nois
e (dBa)
Soun
d power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.
95.2
at 70 psi and 50 cpm
95.2
at 4.8 bar and 50 cpm
Sound Power
101.8 at 100 psi and full flow 101.8 at 7.0 bar and full flow
87.3
at 70 psi and 50 cpm
87.3
at 4.8 bar and 50 cpm
Sound Pressure
94.7 at 100 psi and full flow 94.7 at 7.0 bar and full flow
Fluid flow per cycle
Standard diaphragms
1.6
gallons
6.1
liters
Overmolded diaphragms
1.3
gallons
4.9
liters
Maximum free-flow delivery
Standard diaphragms
20
0gpm
75
7lpm
Overmolded diaphragms
20
0gpm
75
7lpm
2
2
3A2578B