Installation
Air Exhaust Ventilation
If pumping tox
ic fluids, you must vent the exhaust
away from peo
ple, animals, food handling areas,
and all sourc
es of ignition. Follow all applicable
codes.
NOTICE
The air exhaust port is 1 in. npt(f). Do not restrict
the air exhaust port. Excessive exhaust restriction
can cause erratic pump operation.
To provide a remote exhaust:
1. Removethemuffler(U)fromthepumpair
exhaust port (K).
2. Install a grounded air exhaust hose (S) and
connect the muffler to the other end of the hose.
The minimum size for the air exhaust hose is 1
in. (26 mm) ID. If a hose longer than 15 ft (4.57
m) is required, use a larger diameter hose. Avoid
sharp bends or kinks in the hose.
3. Place a container (T) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
AAirs
upply line
KAire
xhaust port
B
Bleed-type master air valve (may be
required for your pump installation)
S Grounded air exhaust hose
C Air filter/regulator assembly
T
Container for remote air exhaust
D
Ma
ster air valve (for accessories)
U
Mu
ffler
J
Air inlet port (not visible)
3A2578B
11