Installation
332291C 9
Choosing an Installation Location
• Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
• Refer to the two mounting hole layouts provided
in the Mounting Pattern section of this manual,
page 33.
NOTE: The two mounting hole layouts provided
in the Technical Data section show the only cor-
rect installation patterns to use for mounting the
G3. No other installation configurations should
be used.
• Use designated mounting holes and provided
configurations only.
• Always mount the G3 oil models upright.
• If the G3 grease model is going to be operated
in a tilted or inverted position for any period of
time, you must use a model that includes a fol-
lower plate, otherwise the G3 must be mounted
upright. Refer to your model number to confirm
if a follower plate was installed on your pump.
See page 4, Understanding the Model Number
to identify this character in your model number.
• Use the three fasteners (included) to secure the
G3 to the mounting surface.
• Some installations may require an additional
reservoir support bracket. Consult your Graco
distributor for assistance with this installation.
AUTOMATIC SYSTEM ACTIVATION HAZARD
If the system is equipped with has an automatic timer (user supplied) that activates the pump lubrication system
when power is connected or when exiting the programming function, unexpected activation of the system could result
in serious injury, including skin injection and amputation.
Before you install or remove the lubrication pump from the system, disconnect and isolate all power supplies and
relieve all pressure.