Technical Data
28 311826C
Technical Data
Pump Performance Charts (see pages 30-32)
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific
flow (lpm/gpm) and operating pressure (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected
operating pressure curve (solid line). Follow left to
scale to read fluid outlet pressure.
Pump Air or Hydraulic Oil Consumption
To find air or hydraulic oil consumption at a specific flow
(lpm/gpm) and operating pressure (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected
operating pressure curve (dashed line). Follow left
to scale to read air or oil consumption.
Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Models, page 3.
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . See Models, page 3.
Maximum air/hydraulic working pressure . . . . . . . . . . . . . See Models, page 3.
Pump cycles per 3.8 liters (1 gal.) . . . . . . . . . . . . . . . . . . Dura-Flo 1800 (430 cc): 9.0
Dura-Flo 2400 (580 cc): 6.5
Fluid flow at 60 cpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dura-Flo 1800 (430 cc): 26.1 liters/min (6.9 gpm)
Dura-Flo 2400 (580 cc): 34.6 liters/min (9.2 gpm)
Motor piston effective area . . . . . . . . . . . . . . . . . . . . . . . . See motor manual, supplied.
Stroke length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See motor manual, supplied.
Lower effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dura-Flo 1800 (430 cc): 18 cm
2
(2.79 in.
2
)
Dura-Flo 2400 (580 cc): 24 cm
2
(3.72 in.
2
)
Maximum pump operating temperature . . . . . . . . . . . . . . 65.5°C (150°F)
Motor fitting sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See motor manual, supplied.
Fluid inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 in. npt(f)
Fluid outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/2 in. npt(m)
Sound pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NXT air motors: See manual 311238, supplied.
Viscount hydraulic motors: 88 dB(A) at 1450 psi hydraulic
pressure, 25 cycles/min (tested in accordance with ISO
3744)
Premier air motor: 83 dB(A) at 100 psi, 15 cycles/min
Sound power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NXT air motors: See manual 311238, supplied.
Viscount hydraulic motors: 103 dB(A) at 1450 psi hydrau-
lic pressure, 25 cycles/min (tested in accordance with ISO
3744)
Premier air motor: 95.9 dB(A) at 100 psi, 15 cycles/min
Wetted parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See manual 311825.