Warnings
332511A 3
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
Overview
System Description
The heated platen kit is a field installed kit to add heat to
the platen. The additional heat may change the viscosity
properties of the material and allow the material to flow
easier through the system.
Power Requirements
A 25A (minimum) - 30A (maximum) circuit breaker must
be installed on the incoming power supply.
* Add to power requirements of ExactaBlend AGP
Advanced Glazing Proportioner system. Amps maxi-
mum per leg shown.
** 190-264 voltage range acceptable.
WARNINGWARNINGWARNING
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric
shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing
or installing equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:
• Do not touch hot fluid or equipment.
Nominal Voltage** Wattage Amps*
240 V 3,500 per Platen 20