Goodmans DSXC18 Air Conditioner User Manual


 
SS-DSXC18 www.goodmanmfg.com 21
Product SPecificationS
Ahri rAtingS (Cont.)


 
 
    SEER² EER³
DSXC18
0601A*
AVPTC60D14A* 58,000 42,000 16.00 11.75 1,780 5924370
CA*F4961*6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357217
CA*F4961*6D*+MBVC2000**-1A*+TXV 58,000 42,000 17.00 12.00 2,000 4431669
CA*F4961*6D*+TXV A*VC950915DXB* 58,000 42,000 16.00 11.50 1,750 5620929
CA*F4961*6D*+TXV G*VC950915DXB* 58,000 42,000 16.00 11.50 1,750 5620930
CA*F4961*6D*+TXV G*VM960805DXB* 58,000 42,000 16.00 11.50 1,750 5620935
CA*F4961*6D*+TXV G*VM960805CXB* 58,000 42,000 16.00 11.50 1,750 5620933
CA*F4961*6D*+TXV G*VM961005DXB* 58,000 42,000 16.00 11.50 1,900 5620937
CA*F4961*6D*+TXV G*VC950905CXB* 58,000 42,000 16.00 11.50 1,750 5620925
CA*F4961*6D*+TXV G*VC950905DXB* 58,000 42,000 16.00 11.50 1,750 5620927
CA*F4961*6D*+TXV G*VC951155DXB* 58,000 42,000 16.00 11.50 1,900 5620931
CA*F4961*6D*+TXV G*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484852
CA*F4961*6D*+TXV G*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484853
CA*F4961*6D*+TXV A*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484851
CA*F4961*6D*+TXV A*VM960805CXB* 58,000 42,000 16.00 11.50 1,750 6497847
CA*F4961*6D*+TXV ADVC80805C*B* 56,000 40,500 16.00 11.20 1,940 6497850
CA*F4961*6D*+TXV ADVC81005C*B* 56,000 40,500 16.00 11.20 1,820 6497851
CA*F4961*6D*+TXV A*VC950905DXB* 58,000 42,000 16.00 11.50 1,750 6497845
CA*F4961*6D*+TXV A*VM961005DXB* 58,000 42,000 16.00 11.50 1,900 6497848
CA*F4961*6D*+TXV A*VC951155DXB* 58,000 42,000 16.00 11.50 1,900 6497846
CA*F4961*6D*+TXV A*VM961155DXB* 58,000 42,000 16.00 11.50 1,900 6497849
CA*F4961*6D*+TXV G*VM961155DXB* 58,000 42,000 16.00 11.50 1,900 5620939
CA*F4961*6D*+TXV A*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484850
CA*F4961*6D*+TXV A*VC950905CXB* 58,000 42,000 16.00 11.50 1,750 6497844
CHPF4860D6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357218
CHPF4860D6D*+MBVC2000**-1A*+TXV 58,000 42,000 17.00 12.00 2,000 3654439
CHPF4860D6D*+TXV G*VC951155DXB* 58,000 42,000 16.00 11.75 1,750 5620932
CHPF4860D6D*+TXV G*VC950905DXB* 58,000 42,000 16.00 11.50 1,900 5620928
CHPF4860D6D*+TXV G*VM960805CXB* 58,000 42,000 16.00 11.50 1,900 5620934
CHPF4860D6D*+TXV G*VM961005DXB* 58,000 42,000 16.00 11.75 1,750 5620938
CHPF4860D6D*+TXV G*VM961155DXB* 58,000 42,000 16.00 11.75 1,750 5620940
CHPF4860D6D*+TXV G*VM960805DXB* 58,000 42,000 16.00 11.50 1,900 5620936
CHPF4860D6D*+TXV G*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484856
CHPF4860D6D*+TXV A*VC80805C*B* 56,000 40,500 16.00 11.20 1,890 6484854
CHPF4860D6D*+TXV G*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484857
CHPF4860D6D*+TXV A*VC950905CXB* 58,000 42,000 16.00 11.50 1,900 6497852
CHPF4860D6D*+TXV A*VM960805DXB* 58,000 42,000 16.00 11.50 1,900 6497856
CHPF4860D6D*+TXV A*VC951155DXB* 58,000 42,000 16.00 11.75 1,750 6497854
CHPF4860D6D*+TXV A*VC950905DXB* 58,000 42,000 16.00 11.50 1,900 6497853
CHPF4860D6D*+TXV A*VM960805CXB* 58,000 42,000 16.00 11.50 1,900 6497855
CHPF4860D6D*+TXV A*VM961005DXB* 58,000 42,000 16.00 11.75 1,750 6497857
CHPF4860D6D*+TXV A*VM961155DXB* 58,000 42,000 16.00 11.75 1,750 6497858
CHPF4860D6D*+TXV G*VC950905CXB* 58,000 42,000 16.00 11.50 1,900 5620926
CHPF4860D6D*+TXV A*VC81005C*B* 56,000 40,500 16.00 11.20 1,800 6484855
CSCF4860N6D*+EEP+TXV 57,000 41,000 15.00 12.00 1,500 5357219
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F

Always check the S&R plate for electrical data on the unit being installed.
When matching the outdoor unit to the indoor unit, use the piston supplied with the out-
door unit or that specied on the piston kit chart supplied with the indoor unit.
EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not in-
terchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling me delay