Goodman Mfg AVPTC313714 Air Conditioner User Manual


 
WIRING DIAGRAMS
10
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
AVPTC
RD
M4
FL
BL
RD
3
BK
BK
L2
RD
YL
8
BK
RD
3
L1
RD
RD
5
BK
FL
TL
FOUR
(
4
)
ELEMENT ROWS
M2
HTR1
4
1
5
M5
2
M2
R
L2
L1
L1
4
RD
BL
L2
FL
1
3
7
RD
THREE (3) ELEMENT ROWS
TL
L2
BL
BL
2
RD
M8
7
RD
5
7
BK
BL
BK
YL
PU
1
BR
YL
FL
TL
9
BK
M1
7
WH
6
BK
RD
BR
TL
BK
5
M1
WH
2
M1
HTR1
PU
M6
BK
FL
HTR1
TL
HTR4
R1
PU
M2
FL
BK
4
6
RD
PU
BK
RD
BK
6
M3
BL
BK
WH
9
M3
BK
R1
M4
RD
8
RD
9
HTR3
R2
4
L1
TL
L1
BL
FL
RD
HTR2
YL
M3
M2
TL
HTR3
TL
ONE (1) ELEMENT ROWS
BL
BK
M1
BK
1
BK
3
M1
RD
L2
9
R2
HTR2
M2
M4
BK
L1
8
TWO (2) ELEMENT ROWS
TL
TL
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER
HTR2
BL
R
6
RD
FL
YL
M7
2
WH
BK
RD
FL
FL
L2
8
HTR1
BK
BK
YL
RD
BK
GY
BL
AF
HEAT
COM
CIRCULATOR BLOWER
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED
WHEN SERVICING.
1
1
SEE
NOTE 5
BK BLACK
OR ORANGE
CIRCULATOR
CIRCULATOR
RD
WH
TO
MICRO
R
W2 (2)
AIR
DIAGNOSTIC
LED
PL1
BL BLUE
4
2
PK PINK
EQUIPMENT GND
SEE
NOTE
7
DEHUM
TERMINAL
GY GRAY
O
PLUG CONNECTION
DEHUM
RD RED
24 VAC
RD
FUSE
4
-
BLWR
LEARN
5
DIP SWITCHES
AIR
40 VA
ADJUST
2
3
LOW VOLTAGE FIELD
1
3
3
HI VOLTAGE FIELD
8
L1
9
INDOOR
7
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND
LOCAL CODES.
BIAS
4
BK
1
5
BL
PL2
WH WHITE
FUSE 3 A
208/230 VAC
GND
JUNCTION
ECM MOTOR
HARNESS
GND
6
L2
6
L1
COM
BR
G
VT VIOLET
UNUSED
MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
G
INTEGRATED CONTROL MODULE
O
1
2
W2
6. BIAS AND TERM DIP SWITCHES MUST BE IN "ON" POSITION. RED
STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES
NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.
BIAS
BK
3
HI VOLTAGE (230V)
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING
MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY
RX LED
4
24V THERMOSTAT CONNECTIONS
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT
1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC
OPERATION.
YL YELLOW
W2
L2
1
DISCONNECT
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.
BR BROWN
SEE NOTE 6
2
BL
Y2
BK
RESISTER
TR
C
1
3
GND (4)
2
2
PROT. DEVICE
INDOOR
INTEGRATED CONTROL
9
RD
TH
+VDC (1)
Y1
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT,
DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N
THERMOSTAT INPUTS)
ELEC
STATUS
LED
TH
B
K
Y2
COLOR CODES:
RX (2)
RD
GND
4
24 V
3 A
W1
GND
4
LOW VOLTAGE (24V)
NOTES:
GN
Y1
R
CFM LED
W1
8
FIELD SPLICE
5
W1 (1)
C
R
D
DEHUM
TX (3)
BL
INTERNAL TO
3
FIELD GND
GND
TERM
HEAT SEQUENCER R2
RD
TRANSFORMER
DELAY
COOL
GN GREEN
24 V THERMOSTAT CONNECTIONS
HEAT SEQUENCER R1
GN
7
TR
OVERCURRENT
2
BLW R
0140A00039 REV.C
6. BIAS AND TERM DIP SWITCHES MUST BE IN "ON" POSITION. RED
STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES
NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING
MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY
1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT,
DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N
CIRCULATOR BLOWER
4
2
3
4
2
3
1
ECM MOTORECM MOTOR
HARNESS
3
1
ECM MOTOR
1
2
SEE
NOTE 5
DEHUM
DIP SWITCHES
ADJUST
1
BIAS
UNUSED
BIAS
SEE NOTE 6
BL
ELEC
STATUS
LED
4
CFM LED
5
TERM
DELAY
COOL
0140A00039 REV.C