GE AZ39H12DAC Heat Pump User Manual


 
AZ39H12DAC
GE Zoneline
®
Deluxe Series Heat Pump Unit
Specification Created 2/08
390584
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Electrical Wiring
All wiring, including installation of receptacle, must be made in accordance with local
electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) RAG63 (Bittersweet)
RAG62 (Maple) RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps.
RAK40 – Deflector Kit to adapt chassis for use with existing
exterior architectural louvered grilles.
Ducted Applications
2900 and 3900 series can be used with ductwork to heat or cool more than one
room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct
Extension is applied to right or left of adaptor. Locally fabricated ductwork may be
added to extend to maximum recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with
a junction box and require direct
connection. (NEC Requires 265V Direct Connection) See Architects and Engineers
Design Data Manual for electrical
connection information including use of sub-base for direct connected units.
Installation must comply with local electrical codes and regulations.
Power Connection kits required on all Zoneline chassis.
Wall Case Dimensions
RAB71 Wall Sleeve
Heavy-gauge galvanized steel, with insulation.
A – 42", B – 13-3/4", C – 16"
RAB77 Wall Sleeve
Molded SMC fiberglass-reinforced polyester compound.
A – 42-1/8", B– 13-7/8", C – 16-1/4
Wall Opening Dimensions
Add 1/4" to A and C dimensions for all cut-out size.
RAB71 16-1/4" Min. H x 42-1/4" Min. W
RAB71 available in 16", 24", 28" and 31" depths
RAB77 16-1/2" Min. H x 42-3/8" Min. W
Maximum Cord Extension
SIDE
VIEW
Inside
Room
Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
Dimensions and Installation Information (in inches)
230/208 Volt Line Cord Connected Units
Line Cord
Kit
Electric Heat
(Btuh)
Electric
Heater Watts
Electric
Heat Amps
Min. Circuit
Protection
(Amps)
RAK3153 8,600/7,100 2,550/2,090 11.6/10.6 15
RAK3203 11,700/9,600 3,450/2,820 15.5/14.1 20
RAK3303 17,000/13,900 5,000/4,090 22.3/20.3 30
230/208 Volt Sub-Base Connected Units
Sub-Base
Electric Heat
(Btuh)
Electric
Heater Watts
Electric
Heat Amps
Min. Circuit
Protection
(Amps)
RAK204D15P 8,600/7,100 2,550/2,090 11.6/10.6 15
RAK204D20P 11,700/9,600 3,450/2,820 15.5/14.1 20
RAK204D30P 17,000/13,900 5,000/4,090 22.3/20.3 30
A
C
B
Zoneline RAC Wall Installation