INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
Covering Models:
MANHATTAN - 8619 - P8619
Packing Checklist
Qty Description
1 Stove
1 Flue Blanking plate
1 Flue In fill plate
1 Coal set*
1 Flame Baffle*
1 Front Coal*
1 Fixing kit containing
1 Instruction Manual
2 Wood screws
2 Rawlplugs
1 Box spanner
*Packed in appliance
Model
CAT.
Gas Gas
Type
Working
Pressure
NOX
Class
Aeration Injector Gas Rate
m3h
Input kW (Gross) Country
High Low
Steel Manhattan 8619
I
2H
Naural Gas G20 20 mbar 5 ø11 mm 375 0.629
6.6
Gross
6.6
Gross
GB,IE
Steel Manhattan P8619
I
3+
LPG Propane G31
LPG Butane G30
37 mbar
29 mbar
5 ø15.5 x 2 170
0.237
0.18
6.30
Gross
3.25
Gross
GB,IE
Efficiency Class II
Flue Outlet Size 127 mm (5”) ø
Gas Inlet Connection Size 8 mm ø
Minimum flue specification T300/N2/O/D/1
Maximum flue temperature 260°C
A
AAAA
B
D
E
C
A B C D E
ins mm ins mm ins mm ins mm ins mm
27
7
/
8
709 27 683 16
3
/
4
42 17
7
/
8
453 5
3
/
4
145