Stovax AR0369 Indoor Fireplace User Manual


 
1.12 In all correspondence, please quote the appliance type and
serial number which can be found on the databadge at the
rear of the stove.
1.13 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the Model No. and Serial
No. Please ensure the commissioning checklist is completed
by your installer; this is a requirement of your Guarantee.
2.1 Locate the control valve on the appliance. There are two
control knobs on the valve:
- right controls the pilot ignition
- left controls the main burner.
2.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided
with the upgrade to operate the remote control. The
following instructions work for either situation.
2.3 Ensure that the left-hand control knob is pointing to off ( ).
2.4 Ensure that the right-hand control knob is pointing to off ( ).
2.5 Press in the right-hand control knob and, keeping he knob
depressed, turn it anti-clockwise until a click is heard and
the knob is pointing to pilot ( ). The pilot should now
light. If the pilot does not light, release the knob and repeat
the procedure until it does.
2.6 Keep the control knob pressed in for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedures until it remains lit.
2.7 If the pilot does not light after repeated attempts, contact
the retailer or installer from whom the appliance was
purchased.
2.8 Turn the right-hand control to point to main burner ( ).
The appliance can now be controlled using the left-hand
control knob.
2.9 Turn the left-hand control knob to point to low fire ( ),
the main burner lights on low. The burner can now be
controlled between low and high settings. Turn the control
knob anticlockwise to increase the flame height and
clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS REACHED SUFFICIENT HEAT - TYPICALLY 10 TO 20
MINUTES.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RE-
LIGHT THE APPLIANCE.
4
USER INSTRUCTIONS
1.1 Installation and servicing must be carried out by a
competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998, the relevant British
Standards for Installation, appropriate Codes of Practice and
in accordance with the manufacturers instructions. It is a
requirement that a CORGI registered engineer be used for
this purpose as they are approved by the HSE under the
above regulations.
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 29mbar (Butane) or 37mbar (propane).
1.3 The installation shall also be completed in accordance with:
The Building Regulations issued by The Department of The
Environment.
The Building Standards (Scotland) Regulations issued by the
Scottish Development Department.
For Republic of Ireland, reference should be made to the
relevant standards governing installations (IS813:1996)
1.4 Read all these instructions before commencing installation.
1.5 This appliance must be installed in accordance with the
rules in force and only used in a sufficiently ventilated
space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is at least a clearance of 300mm between the
sides of the stove and any curtains.
1.7 The manufacturer considers the full outer casing of this
stove to be a working surface which becomes hot whilst in
operation. A suitable guard is recommended to protect
young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in diagram 1.
1.11 Contact a competent service engineer to carry out relevant
spillage checks etc. following home improvements carried
out after installation of this stove (e.g. the fitting of double
glazing).
1. GENERAL
2. LIGHTING THE APPLIANCE
1
2
AR0914