Stovax AR0369 Indoor Fireplace User Manual


 
2.7 The stove is fitted with the Gazco Flue Sure System, which
acts to cut off the gas supply to the appliance in the event
of incorrect operation of the flue. If the system acts to shut
off the gas supply, this indicates there is insufficient flue
pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system and a qualified gas engineer must inspect.
DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT
IS SAFE TO DO SO.
2.8 Do not tamper with the Flue Sure System Use only genuine
Gazco replacement parts when servicing the system - refer
to Servicing Instructions, Replacing Parts.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20
MINUTES.
3.1 Open the carton containing the engine assembly, and
carefully remove the engine. It will now be necessary to
decide upon top or rear flue exit, the stove is factory built
for rear flue exit, but it may be changed to top exit by
simply using the following method.
3.2 Remove the flue spigot from the rear of the stove and
replace with the blanking plate from the top of the stove.
Refit flue spigot to top of stove.
3.3 When installing with a top flue please note the flue pipe fits
through a hole in the top grill, the dimensions are for floor
fixing a top flue installation with clearance for side panels.
3.4 Position the engine assembly in its intended location and
mark the position of the two floor fixing holes at the base of
each side of the subframe, minimum fixing dimensions to a
rear wall are shown in diagram 2.
10
IMPORTANT: ENSURE THAT THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF USE.
REFER TO DATABADGE AND TECHNICAL
SPECIFICATIONS OF THIS BOOKLET.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES
REFER TO SERVICING INSTRUCTIONS, REPLACING
PARTS.
1.1 This stove is fitted with a control valve that can be easily
upgraded to battery powered remote control. There are two
versions of this control which can be obtained through your
local Gazco stockist.
1.2 This upgrade can be fitted before or after installation but if
side clearances are limited then it will be easier to upgrade
the stove before installation. Full instructions are included
with the kit.
1.3 STANDARD REMOTE CONTROL. This remote controls the
gas appliance after the pilot has been lit. It can turn the
main burner on and regulate it from low through to high
and back again. It can turn the main burner off leaving the
pilot burning GAZCO PART NUMBER 8455.
1.4 THERMOSTATIC AND TIMER REMOTE CONTROL. This
remote controls the gas appliance after the pilot has been
lit. In ‘MANUAL MODE’ it can be used to turn the main
burner on and manually regulate it from low through to
high and back again. It can also be used to turn the main
burner leaving the pilot burning. In ‘AUTO MODE’ it will
automatically regulate the room temperature to a pre-set
temperature. In ‘TIMER MODE’ it will turn the fire on and
off according to a pre-set programme and automatically
regulate the room temperature during the two ON periods.
GAZCO PART NUMBER 8456.
2.1 This appliance must be installed in accordance with the
rules in force and used only in a sufficiently ventilated
space. Place read these instructions before installation and
use of this appliance.
2.2 All the instructions must be left intact with the user.
2.3 In your own interest, and those of safety, this appliance
must be installed by a competent person in accordance
with local and national codes of practice. Failure to install
the appliance correctly could lead to prosecution.
2.4 This appliance is intended for use on a governed gas
installation and set to the required pressure.
2.5 Keep all plastic bags away from young children.
2.6 Do not place any object on or near to the stove. Allow
adequate clearance above the stove. See diagram 2,
Appliance Location..
INSTALLATION INSTRUCTIONS
INSTALLATION
1. CONTROL UPGRADE
2. SAFETY PRECAUTIONS
1
3. INSTALLATION OF THE STOVE