PM190-Issue 1 (October 2006)
Fitting Cast front panel (8901 / 8902 / 8903)
Ensure that the oor of the replace opening is level with
the projecting hearth surface. If a cement inll is required to
achieve this, do not proceed with the installation until the
cement is completely dry.
Cover the surface of the hearth to protect it from damage
during installation of the cast panel.
Protect the surfaces of the surround (mantelpiece) from damage
when trial tting of the panel.
Position the front panel centrally in the replace opening
against the wall. Place the surround (mantelpiece) in position
and, holding it rmly against the wall, pull the front panel
forward until it touches the rear of the surround. The panel is
now in the correct position and should be xed. The surround
can be removed while this is completed.
There are a number of ways of xing the front panel, but a
typical method is:-
Drill through the 4 corners of the main panel in a position that
will be covered when the surround is in position. Drill holes in
the wall in corresponding position, and secure the front panel
with 75mm (3”) screws and non-plastic wall plugs. Fill any
gaps between the wall and the panel with a non-combustible
material, such as breglass rope seal or Stovax re cement, to
form airtight seal.
Never use strong Portland cement mortar in chimneys and
replaces. A lime based mortar will allow expansion and
movement and reduce the risk of cracking.
Wait until any cement or seals are dry before tting a wooden
surround. If the surround is wood, x Stovax at rope seal (Part
No. 4953) to all surfaces that touch the cast iron panel. Place it
into position ensuring that it is central, and secure it to the wall
using at brass brackets (mirror plates).
With Solid fuel res use only at a low re for the rst few hours
of use to allow the castings to temper.
During this time the replace may give off some unpleasant
odours, and we recommend that you keep the room well
ventilated to avoid a build-up of fumes.
Safety
As with all replaces the surfaces will become very hot when
in use, therefore due care should be taken when near the
replace. If it is to be used in the presence of young children,
elderly or inrm persons a suitable reguard should be used.
Care should also be taken with the placement of combustible
items near the replace as conducted and radiated heat could
cause a re hazard.
Stovax offer a wide range of rescreens and sparkguards, along
with a hearthgate system designed to offer full protection for a
range of stoves and replaces. Your Stovax dealer can advise
you on these products.
If a chimney re occurs evacuate all persons from the building
before calling the re brigade. Do not re-enter the building
until it is conrmed safe to do so.
Following a chimney re do not use the replace until it is
inspected, by a HETAS (GB only) registered installer, to conrm
that the appliance is safe to use, or make any repairs required
before re-use. Only genuine Stovax replacement parts are to be
used to keep your replace in safe and efcient working order.
After any chimney re it is recommended that the chimney
system be inspected and swept by a NACS registered (UK only)
chimney sweep, to conrm that the system is structurally sound
and free from any obstructions before re-use.
MAINTENANCE
For fully polished replaces Stovax Steel Cleaner (Part No.
2037) is recommended to keep them clean and rust free. If
a re is not to be lit for an extended period, it is advisable
to coat with a light oil to prevent moisture in the air causing
surface rust and pitting of the cast iron. This is important when
plastering or other decorating work is being done.
E & OE.
INSTALLATION
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF
Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com
IMPORTANT
Please read these instructions carefully before using the appliance.
Keep them safe for future reference and when servicing the stove.
This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions
and in some cases the product may require modification. Contact Stovax to obtain further information.