First Alert UL217 Carbon Monoxide Alarm User Manual


 
1
INTRODUCTION
T
hank you for choosing BRK Brands, Inc. for your Smoke and Carbon
Monoxide Alarm needs. You have purchased a state-of-the-art Smoke &
C
O Alarm designed to provide you with early warning of a fire or Carbon
M
onoxide.
K
ey features include:
S
moke & Carbon Monoxide Combination Alarm.
O
ne alarm protects
a
gainst two deadly household threats.
I
ntelligent Sensing Technology
d
esigned to help reduce unwanted or
nuisance alarms.
Smart Interconnect can be interconnected to BRK Smoke Alarms.
O
ne interconnect wire carries both smoke and CO alarm signals.
S
ingle Button Test/Silence
e
liminates confusion. Depending on what
m
ode the alarm is in, pushing the button provides different functions
such as testing the alarm, silencing the alarm, re-testing the alarm
w
hen in silence and clearing the Latching feature.
L
atching Alarm Indicator
e
asily identifies initiating alarm even after the
a
larm condition has subsided.
Perfect Mount System includes a gasketless base for easy installation
a
nd a new mounting bracket that keeps the alarm secure over a wide
r
otation range to allow for perfect alignment.
D
ust Cover
i
s included to keep the alarm clean during construction.
E
asy Installation/Maintenance
f
eatures include a large opening in
the mounting bracket for easy access to wiring. A battery pull tab that
k
eeps the battery fresh until the home is occupied. A Side Load Battery
D
rawer allows for easy battery replacement without removing the alarm
from the ceiling or wall.
Improved UV Resistance keeps the alarm from discoloring over time.
A
ll BRK
®
a
nd
F
irst Alert
®
S
moke Alarms conform to regulatory
requirements, including UL217 and are designed to detect particles
of combustion. Smoke particles of varying number and size are
produced in all fires.
I
onization technology is generally more sensitive than photo-
electric technology at detecting small particles, which tend to be
p
roduced in greater amounts by flaming fires, which consume
c
ombustible materials rapidly and spread quickly.
Sources of these
fires may include paper burning in a wastebasket, or a grease fire in
the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for
hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on
each level and in every bedroom of your home.
USER’S MANUAL
Smoke & Carbon
Monoxide Alarm
AACC PPoowweerreedd SSmmookkee &&
CCaarrbboonn MMoonnooxxiiddee AAllaarrmm
wwiitthh BBaatttteerryy BBaacckk--uupp,,
SSiilleennccee FFeeaattuurree aanndd
LLaattcchhiinngg AAllaarrmm
Model SC9120B
I
nput: 120V AC
~
6
0 Hz, 0.09A
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
!
!
P
P
L
L
E
E
A
A
S
S
E
E
R
R
E
E
A
A
D
D
C
C
A
A
R
R
E
E
F
F
U
U
L
L
L
L
Y
Y
A
A
N
N
D
D
S
S
A
A
V
V
E
E
This user’s manual contains important information about your Alarm’s
operation. If you are installing the Alarm for use by others, you must leave
this manual — or a copy of it — with the end user.
Model
S
C9120B
P
rinted in Mexico
M08-0094-006
K1 08/08
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Where To Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where This Alarm Should Not Be Installed . . . . . . . . . . . . . . . . . . . .2
Before You Begin Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How To Install This Smoke/CO Alarm . . . . . . . . . . . . . . . . . . . . . .3-4
Using the Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . .5
How Your Smoke/CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . .6
Understanding the Light and Horn Patterns . . . . . . . . . . . . . . . . . . .6
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
What To Do First–Identify the Type of Alarm . . . . . . . . . . . . . . . . . . .6
What To Do if CO is Detected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
What To Do if Smoke is Detected . . . . . . . . . . . . . . . . . . . . . . . . .6-7
“Smart Interconnect” Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
The “Latching Alarm” Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . .8
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . .8
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . .8
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . .8
Regulator
y Infor
mation For Smoke/CO Alar
ms
. . . . . . . . . . . . . . .8-9
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . .8
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . . . .9
About Smoke Alarms
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . .9
General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . .10
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
© 2008 BRK Brands, Inc. All rights reserved.
Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005
www.brkelectronics.com • www.firstalert.com
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately
if they are not working properly. Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every
floor
, and an additional one in the kitchen. Have fire escape ladders or
other reliable means of escape from an upper floor in case stairs are
blocked.
BASIC SAFETY INFORMATION
• Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations.
Pay special attention to these items.
• This Smoke/CO Alarm is approved for use in single-family
residences. It is NOT designed for marine or RV use.
This combination Smoke/Carbon Monoxide Alarm has two
separate alar
ms. The CO Alar
m is not designed to detect fire
or any other gas. It will only indicate the pr
esence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
pr
esent in other ar
eas. The Smoke Alarm will only indicate the
presence of smoke that reaches the sensor. The Smoke Alarm
is not designed to sense gas, heat or flames.
Continued...
LISTED TO
UL 217 and
UL 2034
STANDARDS