First Alert CO511CN Carbon Monoxide Alarm User Manual


 
USER’S MANUAL
Printed in Mexico
M08-0195-000
Q 03/07
1
ONELINK
®
BATTERY OPERATED
CARBON MONOXIDE ALARM
3055574
UL STANDARD 217
Model CO511
Featur
es:
ONELINK
®
Enabled
V
oice with Programmable Location
T
wo Latching Features
Two Silence Features
IMPOR
TANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Carbon
Monoxide Alarm’s operation. If you are installing this Alarm for use by others,
you must leave this manual—or a copy of it—with the end user.
BASIC SAFETY INFORMATION
• Dangers, Warnings, and Cautions alert you to important operating
instructions or to potentially hazardous situations. Pay special
attention to these items.
• This CO Alarm is approved for use in single-family residences.
The CO Alarm is not designed to detect fire or any other gas. It will
only indicate the presence of carbon monoxide gas at the sensor.
Carbon monoxide gas may be present in other areas.
• This CO Alarm cannot operate without working batteries.
Removing the batteries for any reason, or failing to replace the
batteries at the end of their service life, removes your protection.
• NEVER ignore any alarm. See “If Your CO Alarm Sounds” for more
information on how to respond to an alarm. Failure to respond can
result in injury or death.
• The Silence Features are for your convenience only and will not
cor
r
ect a pr
oblem. See "Using the Silence Features" for details.
Always check your home for a potential problem after any alarm.
Failure to do so can result in injury or death.
• Test this CO Alarm once a week. If the Alarm ever fails to test
cor
r
ectly
, have it replaced immediately! If the Alarm is not working
properly, it cannot alert you to a problem.
• This product is intended for use in ordinary indoor locations of
family living units. It is not designed to measure CO levels in com-
pliance with Occupational Safety and Health Administration (OSHA)
commercial or industrial standards. Individuals with medical condi-
tions that may make them more sensitive to carbon monoxide may
consider using warning devices which provide audible and visual
signals for carbon monoxide concentrations under 30 ppm.
For additional information on carbon monoxide and your medical
condition contact your physician.
UL ST
ANDARD
2034
INTRODUCTION
Thank you for choosing First Alert
®
for your Carbon Monoxide Alarm needs.
Y
ou have purchased a state-of-the-art Alarm designed to provide you with
early warning of a carbon monoxide danger. Key features include:
ONELINK
®
Enabled. Alarm automatically communicates with other ONELINK
®
enabled alarms when installed.
Exclusive V
oice Warning with Location
will tell you the pr
eprogrammed
location of the initiating unit and danger detected. Pr
ogrammable up to 11
locations (ex. "basement"). When alarms sounds, if programmed for basement
it will say "W
arning, evacuate, carbon monoxide in basement" along with all
other installed ONELINK
®
V
oice alarms.
Spr
ead Spectrum Horn Tone.
Lower and varying hor
n frequency makes it
easier for elderly with normal age related hearing loss to hear horn. Sweeps
thr
ough the 2200 – 3400 Hz range.
RF Inter
connect.
Reliable and secur
e radio frequency communication
between alarms. 915MHz frequency with 65,000 security codes and 3 channel
fr
equency hopping.
Single Button Test/Silence eliminates confusion. Depending on what mode
the alarm is in, pushing the button pr
ovides different functions such as testing
the alarm, silencing the alarm, re-testing the alarm when in silence and clearing
the Latching features.
Two Silence Features. Temporarily silence low battery chirp for up to eight
hours befor
e replacing low battery or silence an unwanted alarm for several
minutes.
Two Latching Features. Alarm Latch: Easily identifies initiating alarm even
after alarm condition has subsided. Low Battery Latch: Identifies which unit is
in low battery condition.
Perfect Mount System includes a gasketless base for easy installation and a
mounting bracket that keeps the alarm secure over a wide rotation range to
allow for perfect alignment.
6 Y
ear End of Life Timer.
Every 24 hours of operation a counter stor
ed in
memory is updated. When the count equals 6 years of true operation meaning
actually powered-up, a malfunction chirp (triple chirp) will sound once a minute
at the time of the 45 second Power-LED flash.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Wireless Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Step By Step Guide to Programming This Alarm . . . . . . . . . . . . . . . . . . . .4
Adding and Linking Additional ONELINK
®
Alarms . . . . . . . . . . . . . . . . .4
What You Will See and Hear With This Alarm . . . . . . . . . . . . . . . . . . . .4
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Silencing the Low Battery Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Latching Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
What is CO?
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Symptoms of CO Poisoning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
Finding the Source of CO after an Alarm . . . . . . . . . . . . . . . . . . . . . . . .6
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .6
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . . . .6
Regulatory Information For CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Underwriters Laboratories Inc. UL 2034 . . . . . . . . . . . . . . . . . . . . . . . .6
General Limitations Of CO Alar
ms
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
T
r
oubleshooting Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7