Falcon U108610-07 Stove User Manual


 
35
11. Technical Data
This cooker is designed for use on Natural Gas, although a
conversion for LP (
LPG X Propane (2.54 kPa)
) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia
Connection & Test Pressures
Gas (Rp ½ at rear right-hand side) Electric
Natural Gas 1kPa 230 V 50 Hz
Propane 2.54 kPa
See appliance data badge for test pressures.
Dimensions
Overall height minimum 900 mm maximum 925 mm
Overall width 900 mm
Overall depth 600 mm (to fascia); 650 mm (over handles)
Minimum space above hotplate 650 mm
Refer to ‘Positioning the Cooker’.
Ratings
Hotplate
Natural Gas 1.0 kPa LP Gas 2.54 kPa
Input Injector Bypass Input Injector Bypass
Wok burner 15.2 MJh
-1
internal 112
90 15.0 MJh
-1
internal 66
54
external 164 external 91
Large burner 12.3 MJh
-1
165 80 12.0 MJh
-1
89 41
Medium burners 6.2
MJh
-1
115 56 6.2 MJh
-1
67 33
Small burner 3.7 MJh
-1
92 48 3.3 MJh
-1
48 25
Gas burner inputs based on Gross Caloric Value.
Oven Efficiency
Ovens
Main oven Tall oven
Forced air convection Forced air convection
Maximum power output @ 230 V 50 Hz 2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.90 kWh 0.99 kWh
Usable volume (litres) 69 66
Size Large Large
Time to cook standard load 38 minutes 49 minutes
Surface area of the grid 1400 cm
2
790 cm
2
Grill 2.3 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.4kW.