Everpure H-300 Water System User Manual


 
ENGLISH
• 3 •
H 1200 customers: Instructions for installing the H-1200 begin
on page 5 of this Installation and Operation Guide.
BASIC INSTALLATION INSTRUCTIONS
Tools Needed For Installation
Phillips Screwdriver
Wrench
Utility Knife
Measuring Tape
Pencil
OPEN CARTON & INSPECT PARTS
Installation Parts
Key Description Part No.
1 QL3 Filter Head EV9258-01
2 Filter Cartridge (varies)
3 2 Locking Washers EV3062-04
4 2 Screws EV3061-96
5 Angle Stop Valve Adaptor EV3121-20
6 Tubing, 1/4" poly A08601-19
7 Elbow Fitting Pack Restrictor EV3081-68
8 Teflon
®
Tape EV3121-19
9 Faucet Connector EV3121-35
10 Everpure Filter Timer EV9075-70
VERIFY UNDER-SINK MOUNTING LOCATION
Measure 22” from the base of the cabinet, and mark the
mounting location for the top of the filter head. Make sure there
is adequate space above the head to open and close the built in
shut-off valve and to avoid crimping the water line tubing. Also,
make sure your chosen location offers easy access for future
cartridge changes..
DIMENSION Width Height Depth
H-54 5" 15" 5"
H-104 5" 20" 5"
H-300 5" 22" 5"
H-300 +M 5" w/monitor 22" 5"
H-300-HSD 5" 22" 5"
NOTE: The head and cartridge must be mounted in the vertical
position, with the cartridge hanging down.
1.
2.
2
WATER FILTER MONITOR
www.everpure.com
1
1
2
3
5
6
7
8
9
10
4
Model H-54
Rated Capacity:
750 G (2835 L)*
Model H-104
Rated Capacity:
1,000 G (3780 L)*
Model H-300
Rated Capacity:
300 G (1140 L)*
Model H-300-HSD
Rated Capacity:
300 G (1140 L)*
Model H-300+M
Rated Capacity:
500 G (1892 L)*
Model H-1200
Rated Capacity:
1,000 G (3780 L)*
* For optimum performance, cartridge
replacement is required once a year, or sooner
if flow becomes too slow for convenience, or if
the unit’s rated capacity is reached.
The Universal Plumbing Code adopted by over 20
states, and other specific state and county codes prohibit the use of
saddle valves and their use is never recommended. You must adhere
to your state/local plumbing codes. Consult your licensed plumber if
you have related questions.
Do NOT use copper tubing with the John Guest
Fittings provided with your Everpure Filter System. Copper tubing
may appear to fit, but water leaks will develop over time and use. If
copper tubing is required, you must use copper compression fittings
available from any hardware/plumbing supply.
THE OWNER’S GUIDE IS APPLICABLE FOR THE FOLLOWING
EVERPURE FILTER MODELS:
Multiple Appliance Connections: You can also connect your
Everpure Filter to the refrigerator for ice and water, an instant hot
dispenser or chiller, or a plumbed-in coffee brewer. Simply install
connection “tees” (available from any hardware/plumbing supply)
in the water line between the filter and the faucet adaptor, and run
new tubing to each appliance.
NOTE: DO NOT connect this system to a commercial ice maker.
These appliances require flow and volume beyond the design limits
of your under-sink filter system.
NOTE: If connecting to a home icemaker and there is no filter faucet
connection under the sink: A flush valve is required.
22 "