England's Stove Works 55SHP22 Stove User Manual


 
P.O. Box 206 Monroe, VA 24574 www.englanderstoves.com Phone: (800) 516-3636 Fax: (434) 929-4810
Pellet Stoves
Wood Stoves
Gas Stoves
Mult
i
-
F
uel
S
toves
Installing the PU-DTSTAT
BEFORE BEGINNING THERMOSTAT INSTALLATION BE CERTAIN
THE STOVE IS UNPLUGGED
AND COMPLETELY COOL. DEPENDING
ON WHICH STOVE THE THERMOSTAT IS BEING INSTALLED ON,
THE CONTROL BOARD MAY NEED TO BE REMOVED FOR
INSTALLATION.
1. Using a small, slotted screwdriver (often referred to as a jeweler’s screwdriver),
loosen the two screws on the front of the J18 thermostat terminal, shown below
and remove the jumper which is installed in the terminal from the factory. This
jumper should be set aside and saved.
2. Insert one of the thermostat wires into each of the terminals on the bottom of the
J18 thermostat connection block and tighten the screws on the front of the
thermostat terminal. The thermostat wires should be securely held in place by
these screws (remember that the thermostat is not polarity specific, so it will not
matter which wire goes into either terminal).
Connect
thermostat
wires here
(
J18
)