Empire Comfort Systems FAW-55SPP Furnace User Manual


 
12428-3-0706 Page 12
Model No. FAW-55 may be vented as shown. The vent cap must
be at least 12 feet (3.7m) above the floor. Clearance to combus
-
tible construction is held by the fixed spacers at 1 inch (25mm)
with B-1 vent pipe. Installation must conform to local codes.
4” (102mm) Round (all parts purchase locally except in item 2)
1. Type B-1 round pipe
2. Part No. DV-648, 4” (102mm) oval-to-round flue adapter kit
(see accessories)
3. Single story type B-1 gas vents require a baseplate and one
pair of ceiling plate spacers.
4. Multi-story type B-1 gas vents require a baseplate, one pair
of ceiling plate spacers at the first floor ceiling and one pair
of fire stop spacers at each successive ceiling level.
4” (102mm) Oval (all parts purchase locally)
1. Type B-1 oval pipe
2. Single story type B01 gas vents require a baseplate and one
pair of ceiling plate spacers.
3. Multi-story type B-1 gas vents require a baseplate, one pair
of ceiling plate spacers at the first floor ceiling and one pair
of fire stop spacers at each successive ceiling level.
4” (102mm) Oval In-The-Wall
(wall parts purchase locally)
1. Type B-1 oval pipe
2. Type B01 oval elbows
3. Single story type B-1 gas vents require a baseplate and one
pair of ceiling plate spacers.
4. Multi-story type B-1 gas vents require a baseplate, one pair
of ceiling plate spacers at the first floor ceiling and one pair
of fire stop spacers at each successive ceiling level.
Stud space around gas vents must be free of obstructions and
building paper.
Accessories
Part No. Description
SOR-1 Register, side outlet, fixed register
SOK-1 Side outlet, 10” (254mm) maximum extension,
fixed register
ROK-1 Rear Outlet, 10” (254mm) maximum extension,
adjustable register
DV-651 Vent enclosure, 14” (356mm) [for rooms up to 96
1/2” (245cm) in height]
DV-655 Vent enclosure, 24” (610mm) [for rooms up to
106 1/2” (270.5cm) in height]
DV-666 Vent enclosure, 36” (914mm) [for rooms up to
118 1/2” (301cm) in height]
DV-648 4” (102mm) Oval-to-Round flue adapter kit
Use U.L. listed gas vent equipment when installing the FAW-55.
For vent pipe running through walls, roof, and within one (1) inch
(25mm) of combustible construction, use B01 [one inch (25mm)
clearance to combustibles] vent pipe. Type B-2 x 4 or Type B-2 x
6 are to be used in conjunction with a Listed fire stop spacer.
Type BW gas vent pipe is available for single story or multi-story
installations, Type BW gas vent pie is to be used with the Listed
base plate, ceiling plate spacers and fire stop spacers.