FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
handle. Never use tools. If the handle will not push in
or turn by hand, don't try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Remove floor register.
NOTE: The gas control handle is attached to the gas
control knob.
4. Push in gas control handle slightly and turn clock-
wise to "OFF."
NOTE: Handle cannot be turned from "PILOT" to
"OFF" unless handle is pushed in slightly. Do not
force.
5. Remove the pilot access cover located on the combustion
chamber.
6. Wait ten (10) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
above. If you don't smell gas, go to the next step.
7. Find pilot - the pilot
is adjacent to the
center portion of the
main burner in the
area directly below
the pilot access open-
ing.
8. Turn gas control handle counterclockwise
to "PILOT."
9. Push and hold control handle in and repeatedly push
the ignitor button until pilot is lit (or use match and
lighter rod to light.) Continue to hold the control
handle in for about one (1) minute after the pilot is
lit. Release handle and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 4 through
9.
If handle does not pop up when released, stop
and immediately call a qualified service tech-
nician or gas supplier.
If the pilot will not stay lit after several tries,
turn the gas control handle to "OFF" and call
your service technician or gas supplier.
10. Replace pilot access cover.
11. Turn gas control handle counterclockwise
to "ON."
12. Replace floor register.
13. Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Remove floor register.
3. Push in gas control handle slightly and turn
clockwise to "OFF." Do not force.
4. Replace floor register.
3588
5088
7088