WLH12 ELECTRICAL SPECIFICATIONS
Volts/
HZ/PH
Fan RLA
Heater
K.W.
Amps
Total
Amps
Min. Volt
M.C.A.
HACR
BRKR
115/60/1 0.64 0.64 104 0.8 15
115/60/1 0.64 .75 6.5 7.14 104 8.9 15
208/230/60/1 0.34 0.34 197 0.4 15
208/230/60/1 0.34 3 13.04 13.38 197 16.7 20
HEAT PUMPS SYSTEM OPTIONS WITH WLH12/S1H2
Cooling
Btuh
Heating
Btuh
SEER HSPF SHR EER COP
11,400 10,600 13.0 8.0 .73 11.5 3.4
WLH
S1H
CAPACITIES:
Cooling ....................11,400 Btuh
Heating (High) ........ 10,600 Btuh
Heating (Low)........... 6,200 Btuh
Indoor Design Temp °F DB/WB
Cooling .............................. 80/67
Heating.............................. 70/57
Outdoor Design Temp °F DB/WB
Cooling .................................95/75
Heating (High) ......................47/43
Heating (Low).......................17/15
S1H ELECTRICAL SPECIFICATIONS
Model Volts/HZ/PH
Total
Amps
Min
Volt
M.C.A.
HACR
BRKR
S1H
2A 115/60/1 10 104 12.2 20
S1H
2D 208/230/60/1 5.1 197 6.2 15
STANDARD FEATURES:
Evaporator
High Wall Mounted
:
• Universalunit mounted,infraredcompatiblecontrol
package,congurabletoeitherunitmountoroptional
wallthermostatoperation.
• Compatiblewithmoststandardwallmounted,24V
thermostats
• Motorizedsupplylouver
• Integraleldcondensatepumpconnector
• Condensatepanoverowprotection
• Anti-shortcyclecompressorprotection
• Indoorcoilfreezeprotection
• Drymodeforhumiditycontrol(optional electric heat
required)
• Memorybackupforautore-startfollowingpower
outage
• Fanpurge
STANDARD FEATURES:
Condenser – Side Discharge / Vertically Arranged:
•R-22refrigerant
•FactoryinstalledLowAmbientcoolingto32°F
•Durateccompressorprotectionpackage
-SuctionAccumulator
-Filterdryer
-Highpressureswitch(manual reset)
-Thermostaticallycontrolledcrankcaseheater
-Startassist
•Coatedwirecoilsandfanguards
•Fiveyearcompressor/oneyearpartswarranty
Thermostatically controlled crankcase heater – This feature
energizes the crankcase heater only when needed, removes
the heater from the electrical circuit at conditions where
it’s not required, saving unnecessary Watts, and increasing
overall system efciency.