Ei Electronics Ei 156TLR Smoke Alarm User Manual


 
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei156TLR DataSht RevB
Model Ei 156TLR Optical
Remote control capability
Tamper proof rechargeable lithium battery back up
High performance optical chamber with integral
insect screen
Test/Hush button
Advanced suppression and calibration technology
Interconnectable to other Ei mains powered alarms
Built in auto self test feature
Low power cell warning
Kitemarked to BS EN 14604:2005
5 year guarantee
Product Description
The Ei156TLR is an Optical Smoke Alarm that runs on
230V AC mains power, and has built in tamper proof
rechargeable lithium cells that act as a battery back up in
the event of mains failure. These rechargeable lithium
cells are designed to have a ten year life and outlast the
life of the smoke alarm itself, whilst providing up to six
months of smoke alarm operation without mains power.
The Ei156TLR allows the detector to be controlled
remotely by either a “Test/Hush” Switch (Ei152), a
“Locate” Switch (Ei159) or a Manual Call Point
(MCP400). If the Ei156TLR is also interconnected to
other Ei mains powered alarms then the whole system
will be controllable remotely.
The Ei156TLR has other advanced features such as
integral insect screens to reduce the chances of false
alarms, as well as the ability to interconnect up to twelve
alarms.
The Ei156TLR has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
Operation
The green indicator will illuminate to show mains
power is present
The red indicator will flash every 40 seconds to
show that the detector has performed an automatic
self test
The red indicator will flash rapidly to show an alarm
condition for the smoke detector
The “Test/Hush” button will either silence false
alarms or perform a unit self test. In “Test” mode the
alarm will perform a self test and sound the horn
In “Hush” mode the alarm enters a ten minute period
of reduced sensitivity to overcome false alarm
conditions, and will then automatically reset itself
When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
The smoke detector will emit a beep and flash the
red light every 40 seconds to indicate that the
battery back up is depleted and needs recharging
The detector can be controlled remotely by either a
“Test/Hush” Switch (Ei152), a “Locate” Switch
(Ei159) or a Manual Call Point (MCP400).
MAINS POWERED 230V~
Rechargeable Battery Back-Up