TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Motion
Motion
The detector is most sensitive to motion across its fi eld
of view.
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will fl ash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
DESA Specialty Products reserves the right to discon-
tinue products and to change specifi cations at any
time without incurring any obligation to incorporate
new features in products previously sold.
Maximum Range Maximum
Coverage Angle
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When fi rst turned
on, wait 1
1
/
2
minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffi c may trigger the control.
Nearby large, light-colored objects refl ecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
180°
MIN MAX
Least Sensitive Most Sensitive
Sensor
WARNING: Risk of fi re. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.