Delta 14178-LHP Plumbing Product User Manual


 
®
®
U
P
C
Submitted Model No.: _______________________________________________
Specific Features: __________________________________________________
STANDARD SPECIFICATIONS:
Pressure balanced single handle bath
mixing valve.
Requires 1 1/2" (38 mm) wall cavity.
Back-to-back installation capability.
Solid brass fabricated body.
Monitor
®
with Scald-Guard
®
valve. Maintains
a balanced pressure of hot and cold water
even when a valve is turned on or off
elsewhere in the system.
Temperature only controlled with handle.
Field adjustable to limit handle rotation into
hot water zone.
120° maximum handle rotation.
All parts shall be replaceable from the front
of the valve.
LHP- less handle program. See available
handle options on back
14178-LHP
14278-LHP
0
1
2
3
4
5
0 102030405060708090
Pressure (PSI)
Flow (U.S. Gallons Per Minute)
6
0 69 138 207 276 345 414 483 552 621
0
3.8
7.6
11.4
15.1
18.9
22.7
Pressure (kPa)
Flow (Liters Per Minute)
Showerhead
Tub Filler
BATH MIXING
VALVES
Leland Series
Tub Only (14178)
Shower Only (14278)
Tub/Shower (14478)
Single Handle
Monitor
®
with Scald-Guard
®
Valve
Pressure Balance
Temperature Only Controlled
with Handle
Universal Fittings
COMPLIES WITH:
ASME A112.18.1
ASSE 1016
CSA B125
Indicates ADA compliance to
ICC/ANSI A117.1
CSA Certified
IAPMO Listed
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only.
8" (203 mm) Min.-
18" (457 mm) Max.
7"
(178 mm)
A
B
2"
(51 mm)
1/2"
(13 mm)
Face of plasterguard
should be flush with
finish wall line
Maximum
Allowable Deviation
Supply
CL Supply
Lines
Dimensions
I.P.S. or C.W.T. 2 3/8" 5/8"
I.P.S. or C.W.T. with stops 5 5/16" 3/8"
A
B
14278 & 14478
14478-LHP
14178
8" (203 mm) Min.-
18" (457 mm) Max.
7"
(178 mm)
A
B
2"
(51 mm)
1/2"
(13 mm)
Face of plasterguard
should be flush with
finish wall line
Maximum
Allowable Deviation
Supply
CL Supply
Lines
Dimensions
I.P.S. or C.W.T. 2 3/8" 5/8"
I.P.S. or C.W.T. with stops 5 5/16" 3/8"
A
B