Delta 1303 Plumbing Product User Manual


 
®
®
U
P
C
Submitted Model No.: _______________________________________________
Specific Features: __________________________________________________
STANDARD SPECIFICATIONS:
Pressure balanced single handle bath
mixing valve.
Requires 1 1/2" (38 mm) wall cavity.
Back-to-back installation capability.
Solid brass fabricated body.
Lever handle.
Monitor
®
with Scald-Guard
®
valve. Maintains
a balanced pressure of hot and cold water
even when a valve is turned on or off
elsewhere in the system.
Temperature only controlled with handle.
Field adjustable to limit handle rotation into
hot water zone.
120° maximum handle rotation.
All parts shall be replaceable from the front
of the valve.
1303
1313
1323
1343
1343-NPS
0
1
2
3
4
5
0 102030405060708090
Pressure (PSI)
Flow (U.S. Gallons Per Minute)
6
0 69 138 207 276 345 414 483 552 621
0
3.8
7.6
11.4
15.1
18.9
22.7
Pressure (kPa)
Flow (Liters Per Minute)
Showerhead
Tub Filler
UL Listed to US and Canadian
Safety Standards
21PL
COMPLIES WITH:
ASME A112.18.1M-1996
ASSE 1016-1996
CSA B125-93
Showerhead GSA A-A-240
Indicates ADA compliance to
CABO/ANSI A117.1-1992
ASSE Seal Authorized
City of L.A. approved
CSA Certified
IAPMO Listed
3 1/2"
(89 mm)
A
7"
(178 mm)
Dimensions
I.P.S. or C.W.T. 2 3/8" 5/8"
I.P.S. or C.W.T. with stops 5 5/16" 3/8"
B
2"
(51 mm)
1/2"
(13 mm)
Face of plasterguard
should be flush with
finish wall line
Maximum
Allowable Deviation
C/L Supply
Lines
Supply
1303/1313/1343
1343-NPS
A
B
3 1/2"
(89 mm)
A
7"
(178 mm)
B
2"
(51 mm)
1/2"
(13 mm)
Face of plasterguard
should be flush with
finish wall line
Maximum
Allowable Deviation
C/L Supply
Lines
Supply
BATH MIXING
VALVES
Valve Only (1303 Series)
Tub Only (1313 Series)
Shower Only (1323 Series)
Tub/Shower (1343 Series)
Single Handle
Monitor
®
with Scald-Guard
®
Valve
Pressure Balance
Temperature Only Controlled
with Handle
Dimensions
I.P.S. or C.W.T. 2 3/8" 5/8"
I.P.S. or C.W.T. with stops 5 5/16" 3/8"
A
B
8" (203 mm)
min.
18" (457 mm)
max.
8" (203 mm)
min.
18" (457 mm)
max.
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only.
2.D.5