Setting up
AIR CONDITIONING WITH INSTALLATION
For more efficient use Pinguino can also be
semi-permanently installed
Fit the flange supplied to the hole.
Fix the hose to the coupling on the
back of the unit (figure A).
Attach the end of the hose to the flan-
ge as shown in the figure E.
15
16
16
15
To install, proceed as follows:
•Make a hole in a outside wall or through
the glass of a window. Check the height
and dimensions given in figure D
30 cm
30 cm
106
MAX 120 cm
MIN 30 cm
When the hose is not attached, close the
hole with the bung on the flange .
NOTE:
When the unit is installed semi-permanently,
we recommend leaving a door slightly open
(1 cm is enough) to ensure an adequate
exchange of air.
15
16
in a window
pane
in the wall: for
optimum results,
insulate the sec-
tion of the wall
with suitable
insu-lating mate-
rial.
in the
wood sill of
a window
D
E
Keep the air hoses as short and free of cur-