Cooper Lighting VRMC Indoor Furnishings User Manual


 
FAIL-SAFE
®
ARCHITECTURAL VANDAL RESISTANT
COOPER LIGHTING
DIMENSIONS
DESCRIPTION
The Fail-Safe VRMC, VRM and
2VRM Series fluorescent
luminaires combine a low
profile, surface modular design
with the latest in energy-
efficient technology. Their
Energy Saving Ballast
complies with Federal Energy
Efficiency Standards while a
dihedral recessed top allows
for cooler operation. Other
features include a die-formed
housing, surface or stem
mounting (single or
continuous row), full seam-
welded corners and a broad
selection of attractive door
frames. U.L. listed and C.S.A.
certified.
VRMC
VRM
2VRM
1' x 4', 2' x 2', 2' x 4'
2, 3, OR 4 LAMPS
VANDAL RESISTANT
LUMINAIRE
Housing is die-formed code
gauge prime CRS. Smooth
sides permit flush joints
when continuous row
mounting. Die-formed
captive lampholder
brackets
Ballasts are CBM/ETL Class
“P” and positively secured
by mounting by mounting
bolts. Pressure lock
lampholders
Electrostatically applied
baked white polyester
powder enamel finish
Positive cam action steel
latches with baked white
enamel finish
Die formed, heavy gauge,
flat steel door with
reinforced mitered corners
and baked white enamel
finish. Positive light seals.
Frame and lens are secured
to housing with 4 or 6
stainless steel TORX
®
screws
For additional options, consult your Cooper Lighting Representative.
Specifications and Dimensions subject to change without notice.
B
C
B
C
B
C
MOUNTING
B
C
C
C
B
B
ABC
VRMC 3 15/16" 12" 48"
1' x 4' (100mm) (305mm) (1219mm)
(2 lamp)
VRM 3 15/16" 12" 48"
1' x 4' (100mm) (305mm) (1219mm)
(3 lamp)
2VRM 3 15/16" 24" 24"
2' x 2' (100mm) (610mm) (610mm)
2VRM 3 15/16”" 24" 48"
2' x 4' (100mm) (610mm) (1219mm)
A
B
Ballast Type
LE3= Energy Saving
Ballast
LEOC8= Energy Saving
Ballast
(T-8 Lamp Only)
EB_ _= Generic Electronic
Ballast
No. of Ballasts
1or 2
Lamp Size
2=T12
8=T8
5=T5 Biax
(For specific electronic
ballast specify brand and
catalog number)
ORDERING INFORMATION
SAMPLE NUMBER: 2VRM-232A-120V-EB81-U
Width
Blank=1'
2=2'
Series
VRMC=1' Width (2 Lamp)
VRM=1' Width (3 Lamp)
2VRM=2' Width
Number of
Lamps
2, 3, or 4lamps
(Not Included)
LTS=Low
Trigger Start
(20 Watt)
HTS=High
Trigger Start
(20 Watt)
Voltage
120=120V
277=277V
347=347V
UNV=Universal
Voltage 120-277
Wattage (Length)
U6=40W (24")
U6T8=32W (24")
20=20W (24")
17=17W T8 (24")
U1-5/8=31W
T8 (24")
BX40=40W
Biax (24")
40=40W (48")
32=32W T8 (48")
Lens Type
ACTF140 = .140 Thick
ACTF187 = .187 Thick
PA375 = .250 polycarbonate with
.125 prismatic overlay
(standard with 6S
option)
Door Type
Standard=Flat White Steel
Door (Leave Blank)
Options
(add as suffix)
GL=Internal Single
Element Fusing
GM=Dual Element
Fusing
EL4=Emergency Lighting
self-contained
SMB=Side Mounted
Ballast For Stem
Applications .
(Recommended For 4
Point Suspension)
RIF1=Radio Interference
Suppressor
EKO=End Plate with 7/8"
KO (Required for
Continuous Row
Mounting)
RLS=Rotor-Lock Socket
(T8 Lamps Only)
6S=Six TORX-head
Screws(3 per side)
SC=Safety Chain