Cooper Lighting TCA 6001 UC Indoor Furnishings User Manual


 
10-32 x1/2"
Pan head screws
(4x)
6.
Repeat sequence tightening all screws to final then(10) inch pounds of torque.
5.
Continue through all screws, following the above sequence, tightening each door screw to five(5) inch pounds of
torque.
1.
To remove door, loosen all ten captive door screws and carefully remove door.
2.
To seal door, tighten each door screw in the order specified above.
3.
Using torque allen driver, and beginning with screw one, tighten screws to five(5) inch pounds of torque.
4.
Next, tighten second screw to five(5) inch pounds of torque.
THRU hole for
captive door screw
(x7)
8
2
6
5
10
2.
Secure visor using all four(4) 10-32 x 1/2" Pan head screws.
9
1
3
4
7
1.
To secure visor to
any
XL fixture, slip visor over previously tightened captive door screws.
Torque Sequence and Visor attachment
for all XL Fixtures
mount fixtures vertically.
Sheet 1 of 1
Supplementary Installation Instructions
ADY080875 REV A(ECN080377)
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
Do not
Torque Sequence and Specifications
Securing Visor to XL Fixture