Cooper Lighting P3 Series Indoor Furnishings User Manual


 
PARALUX III
395
COOPER LIGHTING
Computer designed louver
technology
Die embossed housing/
rugged construction
Louver retained by torsion
springs/positive light seal
Louver/reflector optical
assembly designed for
optimum performance
High shielding
angle/balance low
brightness illumination
Heavy duty adjustable
mounting brackets
Plaster, drywall or ceiling
tile installation
Attractively styled mitered
aluminum fixture trim
Fits into nominal 12"
square opening
Utilizes compact
fluorescent lamp sources
UL/CUL Listed. Suitable for
damp locations.
P3 SERIES
1' x 1' Parabolic
2 or 3 Lamp
Parabolic Louver
PARALUX III
COMPACT PARABOLIC
3=3" Louver
Depth
DIMENSIONS DESCRIPTION
The Paralux III 1' x 1' Compact
Parabolic brings together rugged
construction and compact
fluorescent lamp sources with an
efficient, aluminum parabolic
louver assembly for light control
and design aesthetics. The 1' x 1'
Compact Parabolic is an
excellent low brightness, decor
pleasing luminaire for accent,
corridor, foyer and small office
lighting applications. The series
is an ideal complement to any
standard parabolic installation in
plaster, drywall, or ceiling tile.
NOMINAL SIZE A B C
1' x 1' 15-1/2" (394mm) 7-1/8" (181mm) 12-7/8" (327mm)
Number of
Lamps
2 or 3lamps
(Not included)
Wattage (Length)
TT13=13W Compact
Fluorescent (7-1/2")
OC16=16W T8 (10-1/2")
BX18=18W PreHeat (9-1/2")
BX18=18W Rapid Start (10-1/2")
Options
GL=Single Element Fuse
GM=Double Element Fuse
Starting Type
(Biaxial Only)
PH=Pre-Heat,
Normal Power
Factor (Standard
Biaxial only)
RS=Rapid Start
(18W Rapid Start
Biax only)
Louver Color
S=Silver
Cell Configuration
22=2 Rows of 2, 4 Cell
33=3 Rows of 3, 9 Cell
Louver Finish
I=Semi-Specular/Haze
(Low Iridescent)
MI=Specular/Mirrored
(Low Iridescent)
P=Paralux
Louver
ORDERING INFORMATION
SAMPLE NUMBER: P3-2BX18S22I-RS-120V-U
Voltage
(1)
120V=120 Volt
277V=277 Volt
347V=347 Volt (T8 only)
Ballast Type
(1)
Blank=Standard Magnetic Ballast for PH and RS only
EB8
=T8 Electronic Instant Start.
Total Harmonic Distortion < 20%
(For complete details on generic or to specify manufacturer’s
ballast see pg. 469)
No. of Ballast
1, 2 or 3
Options
(See Options
Section)
Packaging
U=Unit Pack
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
COOPER LIGHTING - METALUX
®