Cooper Lighting CR Series Indoor Furnishings User Manual


 
SURFACE
424
COOPER LIGHTING
DIMENSIONS
Equipped with energy
saving ballasts/complies
with federal energy
efficiency standards
Die formed channel
Heavy gauge end plates
with embossed light seal
Baked white enamel finish
Low brightness/extruded
acrylic refractor
Lift and shift refractor for
ease of re-lamping
Wireway cover easily
removed without tools
Surface or stem mounting,
single or continuous row
(3)
Also available in tandem
8' lengths
Wall mount application
possible by ordering
accessory part number of
CR-WALLKIT.
UL/CUL Listed. Suitable for
damp locations.
DESCRIPTION
The CR Series corridor
wraparound features economy
and energy efficient
performance. CR luminaires
utilizes a low brightness,
extruded acrylic refractor with a
heavy gauge end plate with
embossed light seal for
dependable performance and
good looks. The CR Series is the
perfect complement
wraparound for corridors,
stairwells, small office areas,
commercial spaces, dormitories,
and utility lighting.
CR SERIES
4' or 8' Surface
1 or 2 Lamps
SURFACE CORRIDOR
MOUNT
NOMINAL
LENGTH A B C D
4'/8' 6-1/8" (156mm) 4-5/8" (118mm) 5-5/16" (135mm) 4-1/4" (108mm)
ORDERING INFORMATION
SAMPLE NUMBER: CR-232A-120V-EB81-U
Tandem
Blank=4' Length
8T=8' Length
One Piece 8' Lens
CR=Series
Number of
Lamps
1 or 2lamps
(Not Included)
Voltage
(1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage 120-277
(2)
Wattage (Length)
40=40W T12 (48")
32=32W T8 (48")
96=75W T12 (96")
96=59W T8 (96")
Lens
A=Acrylic Refractor/Lens
Options
GL=Single Element Fuse
GM=Double Element Fuse
Emergency - for EM installed, see EM options table
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Not available when specifying emergencies, voltage must be specific.
(3)
2 point suspension recommended. Endplates with 7/8" KO standard for continuous row mounting.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
Ballast Type
(1)
LE3=T12 Magnetic Energy Saving
EB8
=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1 or 2
Options
(See Options
Section)
Packaging
U=Unit Pack
COOPER LIGHTING - METALUX
®