Compur Gas Detector Carbon Monoxide Alarm User Manual


 
-
27
-
3. The Compur Ex plus in Operating Mode
The Compur Ex plus is available with a standard battery (NiMH, operation time 4 h at 20°C)
or a longterm battery (NiCd, min. operation time 15 h at 20°C).
When leaving the factory, the batteries are fully charged.
3.1 Charging the Compur Ex plus
Both batteries (standard or longterm) can be charged in the same charging station.
Charging stations are available with 1 or 4 slots.
? Switch off your Compur Ex plus when
charging or charge the batteries se-
perately.
? Do not charge your Compur Ex plus in
hazardous areas.
? Compur Ex plus detectors may be
charged only in charging stations from
COMPUR Monitors.
? If your Compur Ex plus detector is not
in use, store it in the charging station.
Charging the batteries:
??Make sure, the switch is in the OFF-
position
??Connect the charging station to the
mains adapter or the optional 12 V car
adapter.
Do not charge the batteries in hazardous areas !