Chamberlain 1270LMC Garage Door Opener User Manual


 
28
Operation of Your Opener
To open the door
manually:
The door should be
fully closed if
possible. Pull down on
the red manual
release handle and lift
the door manually.
To reconnect the door
to the opener, press
the Door Control
push bar.
Activate the opener with any of the following:
The Remote Control Transmitter. Hold push
button down until the door starts to move.
The Door Control. Hold push bar down until the
door starts to move.
The Outside Keylock or Keyless Entry System.
(See Accessories)
When the opener is activated with the safety
reversing sensor installed and correctly aligned:
1. If open, the door will close. If closed, the door will
open.
2. If closing, the door will reverse.
3. If opening, the door will stop (allowing space for
entry and exit of pets and for fresh air).
4. If the door has been stopped in a partially open
position, it will close.
5. If obstructed while closing, the door will reverse.
6. If obstructed while opening, the door will stop.
7. The garage door will reverse in the closing cycle
when the invisible beam is broken. If fully open, the
door will not close when the beam is broken. The
sensor has no effect in the opening cycle.
If the sensor is not installed, or is not aligned correctly,
the door won't close from any remote transmitter. You
can close the door with the Door Control, the Outside
Keylock, or Keyless Entry, however, if you activate
them
until down travel is complete.
If you release them
too soon, the door will
reverse.
The opener lights will
blink for 5 seconds
when the
safety reversing sensor causes the door to reverse.
The Opener Lights will turn on under the following
conditions: When the opener is initially plugged in;
when the power is interrupted; when the opener is
activated. It will turn off automatically after 4-1/2
minutes or provide constant light when the Light
feature is activated. Bulb size is 75 watts maximum.
The lockout feature
prevents the trolley from
reconnecting auto-
matically. Pull the red
manual release handle
down and back (toward
the opener). The door
can then be raised and
lowered manually as
often as necessary. To
disengage the lockout
feature, pull the manual
handle straight down.
The trolley will reconnect
on the next UP or
DOWN operation.
Trolley
Trolley
Release Arm
NOTICE
Manual
Release Handle
(Pull Down)
Trolley
Trolley
Release Arm
NOTICE
Manual
Release Handle
(Pull Down & Back
Towards Opener)
Lockout position
Manual disconnect
position
Weak or broken springs could allow an open
door to fall (either rapidly or unexpectedly),
resulting in serious injury, death or property
damage.
If possible, use the manual release
rope and handle
only
when the door is fully
closed.
WARNING
Lighted Door Control Button:
Lighted Push Bar - Door Control Panel: Press to
open or close the door.
Press again to
reverse
the door during the closing
cycle or to
stop
the door while it's opening.
Light Feature - Door Control Panel: Press the
Light button. If the opener light is
off,
it will turn
on
.
If the opener light is
on,
(even in the 4-1/2 minute
automatic cycle) it will turn
off.
But if you use the Light button to turn the light(s)
on
and then activate the opener, the light(s) will turn
off
after 4-1/2 minutes.
The Light button will not control the opener lights
when the door is in motion.
Lock Feature - Door Control Panel: The Lock
feature is designed to prevent operation of the door
from remote controls. However, the door will
open
and close
from the Door Control push bar, the
Outside Keylock and the Keyless Entry Accessories.
To Activate: Press and hold the Lock button for
2 seconds. The push bar light will flash as long as
the Lock feature is
on.
To Turn Off: Press and hold the Lock button for
2 seconds again.The push bar light will stop
flashing. Normal operation will resume. The Lock
feature will also turn off whenever the "Smart"
button on the opener panel is activated.
Operation of the Door Controls