INSTALL CHASSIS IN SLEEVE (See Figures 6 to 9)
1. Inspect foam gaskets (top, bottom, both sides) on
chassis. Replace foam gaskets if torn or missing.
2. Remove shipping tape from vent door. See Figure 7.
3. Lift chassis level with wall sleeve.
4. Slide chassis into wall sleeve until foam gaskets
rest firmly against front of wall sleeve.
5. Screw chassis to wall sleeve with four 1
3
/
4
-in. long
screws taped to the control box. Screw holes are
located on both sides of the mounting angles of the
chassis. Use only the top and bottom screw holes
on each side. See Figure 9.
IMPORTANT: The gaskets combine with the sleeve
face to create a weather barrier. If the chassis is
installed in a non-Carrier sleeve, this weather bar-
rier may not be effective.
Chassis weighs up to 150 lbs. For personal protec-
tion, seek help when lifting the unit. Lift unit by
holding unit basepan.
Failure to remove shipping tape will prevent fresh
air vent door from opening and may result in dam-
age to the vent door cable.
TOP
GASKET
SIDE
GASKET
BOTTOM
GASKET
COIL TUBE
SHEETS
BOTTOM SCREW
HOLE
TOP SCREW HOLE
FIGURE 8 — UNIT GASKETS
AND TUBE SHEETS
FIGURE 9 — CHASSIS MOUNTING
VENT
DOOR
SHIPPING
TAPE
VENT DOOR
CABLE
FIGURE 7 — LOCATION OF SHIPPING TAPE