Table 3 — Output Pin and Terminal Assignments
LEGEND *Circuit 1.
†Circuit 2.
**U2 is not used on 044 units.
††OFC2 on 034-048 units; OFC3 on 054-104 units.
||
Used on 054-104 units only.
OUTPUT PIN-
TERMINAL
NAME RATING DEVICE
J6-1
Stage 1
Compressor Relay (K1)*
24 vac
CR1
J6-2
Stage 2
Compressor Relay (K2)*
U2**
J6-3
Stage 3
Compressor Relay (K3)*
U1
J6-4
Compressor Relay (K4)† Not Used
J6-5
Stage 5
Compressor Relay (K5)†
CR2
J6-6
Stage 6
Compressor Relay (K6)†
Not Used
J6-7
Economizer Open Relay (K7) EOR
J6-8
Economizer Close Relay (K8) ECR
J5-1
Supply Fan Relay (K9)
115 vac
IFC
J5-2
Morning Warm-Up Relay (K10) HIR
J5-3
Stage 1 Condenser
Fan Relay (K11)
OFC2/OFC3††
J5-4
Stage 2 Condenser
Fan Relay (K12)
OFC4||
J5-5
External Alarm Relay (K13) ALM
ALM
Alarm
CR
Control Relay
ECR
Economizer Close Relay
EOR
Economizer Open Relay
HIR
Heat Interlock Relay
IFC
Indoor (Evaporator) Fan Contactor
OFC
Outdoor (Condenser) Fan Contactor
U—
Unloader