Test Procedures
1. Disconnect the stand from the power source.
2. Remove the wires from the circuit breaker.
3. Check for continuity between the circuit breaker
terminals. Continuity must be present between the
terminals.
If continuity is present as described the circuit breaker
is functioning properly.
If continuity is not present as described, press reset
button and repeat step #3, if continuity is not present
as described, replace the circuit breaker.
Removal and Replacement:
1. Remove the wires from the circuit breaker.
2. Compress the clips on the back side of the recep-
tacle bracket and gently push the circuit breaker
through the opening in the receptacle bracket.
3. Push the new circuit breaker into the opening in
the receptacle bracket until the clips snap into
position.
4. Reconnect the wires to the circuit breaker.
5. Refer to Fig. 3 when reconnecting the wires.
FIG. 3 CIRCUIT BREAKER TERMINALS
P1330
BLU/BLK to Transformer #12
BLU/BLK to Rectifier "AC"
RECEPTACLE ASSEMBLY (SPRING CONTACT)
FIG. 4 RECEPTACLE ASSEMBLY
Location:
The receptacle assembly is located on the lower
front of the receptacle bracket just below the circuit
breaker.
Test Procedures:
1. Clean or replace spring contacts.
Removal and Replacement:
1. Disconnect the stand from the power source.
2. Disconnect the wires from the receptacle assem-
bly.
3. Remove the two #6-32 flat head screws securing
the receptacle to the receptacle bracket.
4. Remove and discard receptacle.
5. Install new receptacle in the receptacle bracket
and secure with two #6-32 flat head screws..
6. Refer to Fig. 5 and reconnect the wires.
FIG. 5 RECEPTACLE TERMINALS
P1380
BLK to (-) Terminal on Rectifier
P1402
RED to (+) Terminal on Rectifier