BRK electronic SC7010BV Smoke Alarm User Manual


 
6
STEP BY STEP GUIDE TO PROGRAMMING
THIS ALARM
For First Time and When Changing Batteries
A
ction:
1
. Insert batteries (2, AA batteries).
A
larm Will Say:
Welcome, First Alert Carbon
M
onoxide and Smoke Alarm.”
No location programmed” if
f
irst
t
ime
o
r “[Location, example:
“Basement”] location programmed”
w
hen changing batteries.
“To select location, press and
h
old test button now.”
2. Press & Hold Test Button if
y
ou would like to program the
location or change the location
of the Alarm. Release button
a
fter Alarm responds.
“To save location, press and hold
t
est button after location is
heard.” Alarm will speak list of
locations (see below).
3. After you hear the location of
w
here you are placing the Alarm,
Press & Hold the Test Button.
“[Location, example: “Basement”]
l
ocation saved.”
If no location is chosen:
No location saved.”
Your Alarm has now been programmed for the location of your choice.
A
vailable locations:
Basement Kitchen Child’s Bedroom
L
iving Room Dining Room Master Bedroom
F
amily Room No Location Guest Bedroom
Office Hallway Utility Room
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
U
nder Normal Operations
V
oice:
S
ilent
P
ower/Smoke LED:
C
onstant Green
Horn: Silent CO LED: Off
W
hen You Test the Alarm
Voice: “Testing.” Horn: 3 beeps, pause, 3 beeps; Voice: “Warning,
e
vacuate smoke in [Location, example: “Basement”].
E
vacuate.”
Power/Smoke LED: Flashes Red in sync with the horn pattern
C
O LED:
O
ff, followed by
Horn: 4 fast beeps, pause, 4 fast beeps;
V
oice:
Warning, evacuate carbon monoxide in [Location, example:
“Basement”]. Evacuate.” Pause. “Highest carbon monoxide
l
evel was [CO level example: _0_
p
pm]”.
Power/Smoke LED: Off
C
O LED:
F
lashes Red in sync with the horn pattern
I
f Battery Becomes Low or is Missing
Voice: “Replace battery in [Location, example “Basement”].”
Repeated every 5 hours
H
orn:
c
hirps once a minute
P
ower/Smoke LED:
F
lashes Green On for 2 seconds/Off for
2
seconds. Low Battery Latch is now engaged.
CO LED: Off
If Alarm is Not Operating Properly (MALFUNCTION SIGNAL)
V
oice:
Detector error in [Location, example “Basement”], please
see manual.” Repeated every 5 hours
H
orn:
T
hree rapid chirps every minute
Power/Smoke LED: Flashes approximately once a minute
C
O LED:
O
ff
Alarm Levels of CO are Detected
H
orn:
4
fast beeps, pause, 4 fast beeps, pause
*
Voice:
Warn
ing, evacuate carbon monoxide in [Location, example:
“Basement”]. Evacuate.” Pause. “Highest carbon monoxide
l
evel was [CO level example: ___ ppm]”.
Horn: 4 beeps, pause, 4 beeps, pause repeating 2 times followed
b
y Voice Warning above.
Power/Smoke LED: Off
CO LED: During Alarm: Flashes Red in sync with the horn pattern.
After Alarm: Flashes Red On for 2 seconds/Off for 2
seconds. CO Alarm Latch is now engaged.
*NOTE: If unit goes into CO alarm, the regular 4 beeps-brief pause
cycle will repeat for fifteen minutes. After fifteen minutes, the pause
will increase to one minute.
Smoke is Detected
Horn: 3 beeps, pause, repeating 8 times
Voice: “Warning, evacuate smoke in [Location, example:
“Basement”]. Evacuate.”
Horn: 3 beeps, pause, repeating 3 times followed by Voice Warning
above.
Power/Smoke LED: During Alarm: Flashes Red in sync with the
horn pattern. After Alarm: Flashes Red On for 2 seconds/Off
for 2 seconds. Smoke Alarm Latch is now engaged.
CO LED: Off
Smoke Alarm is Silenced
Voice: “Horn silenced.
Detector active.”
Hor
n:
Of
f
Power/Smoke LED:
Flashes Red
CO LED: Off
CO Alarm is Silenced
Voice: “Horn silenced.
Detector active.”
Hor
n:
Of
f
Power/Smoke LED: Off
CO LED: Flashes Red