BRK electronic SA720 Smoke Alarm User Manual


 
IMPOR
TANT!
PLEASE READ CAREFULLY AND SAVE.
This user’
s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by
others, you must leave this manual—or a copy of it—with the end user.
USER’S MANUAL
Printed in Mexico
M08-0136-001
K1 08/07
LISTED TO UL 217
Model SA720
INTRODUCTION
Thank you for choosing First Alert
®
for your Smoke Alarm needs. Y
ou
have purchased a state of the art Smoke Alarm designed to provide you
with early warning of a fire. Please take the time to read this manual and
make the Smoke Alarm an integral part of your family’s safety plan.
Key Features of the SA720 Smoke Alarm:
Photoelectric Sensing T
echnology:
Photoelectric Sensors ar
e generally
more sensitive than ionization sensors in detecting smoldering fires
which commonly occur in couches or bedding.
OptiPath 360 T
echnology™:
Patented technology pr
ovides 360° of
dir
ect access to the smoke sensor
.
Single T
est/Silence Button:
Allows you to test the alarm or silence
nuisance alarms. T
esting the Alarm assures you that the unit is functioning
corr
ectly and ready to protect you and your family. The Alarm can be
silenced for up to 15 minutes in the event of a nuisance alarm.
Escape Light
®
: Bright escape light activates when this unit goes into
alarm to illuminate your path to safety.
Battery Drawer with “battery missing” lockout: Allows you to easily
r
eplace the battery with out removing the alarm from the ceiling.
The battery door will not close if a battery has not been inserted thus
alerting you that the unit is not powered and not operating.
Low batter
y warning:
The Alarm will sound a “chirp” once per minute
when the battery needs to be r
eplaced.
Blinking Power Indicator: Confirms that the Smoke Alarm is r
eceiving
power
.
© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH)
3901 Liberty Str
eet Road, Aurora, IL 60504-8122 All rights reserved.
Consumer Af
fairs: (800) 323-9005 • www.firstalert.com
FIRE SAFETY TIPS
Follow safety rules and pr
event hazar
dous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away fr
om childr
en; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload elec-
trical
circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
gr
ease- and debris-fr
ee; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away fr
om flammable materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately
if they ar
e not working properly. Smoke Alarms that do not work cannot
alert you to a fir
e. Keep at least one working fir
e extinguisher on every
floor
, and an additional one in the kitchen. Have fire escape ladders or
other r
eliable means of escape from an upper floor in case stairs are
blocked.
BEFORE YOU INST
ALL THIS SMOKE ALARM
Impor
tant!
Read “Recommended Locations for Smoke Alarms” and
“Locations to Avoid for Smoke Alarms” before beginning. This unit
monitors the air
, and when smoke r
eaches its sensing chamber
,
it alarms. It can give you more time to escape before fire spreads.
This unit can ONL
Y give an early warning of developing fires if it is
installed, maintained and located wher
e smoke can r
each it, and wher
e
all residents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Dif
ferent Type of Smoke Alarms
Battery power
ed or electrical? Different Smoke Alarms provide
dif
fer
ent types of pr
otection. See “About Smoke Alarms” for details.
Know Wher
e T
o Install Your Smoke Alarms
Fir
e Safety
Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping ar
ea. See “Recommended Locations
For Smoke Alarms” and “Locations T
o A
void For Smoke Alarms” for
details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See “Limitations of Smoke Alarms” for details.
Check Y
our Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet r
equirements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
HOW TO INSTALL THIS SMOKE ALARM
THE PARTS OF THIS SMOKE ALARM
FOLLOW
THESE SIMPLE STEPS!
*All First Aler
t
®
Smoke Alar
ms conform to regulatory requirements,
including UL217 and ar
e designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally mor
e sensitive than photoelectric
technology at detecting small particles, which tend to be pr
oduced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spr
ead quickly
. Sources of these fires may include
paper bur
ning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally mor
e sensitive than ionization
technology at detecting lar
ge particles, which tend to be pr
oduced
in gr
eater amounts by smoldering fires, which may smolder for
hours befor
e bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in ever
y bedr
oom of your home.
This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impaired residents.
Do not connect this unit to any other alarm or auxiliary
device. It is a single-station unit that cannot be linked to other
devices. Connecting anything else to this unit may prevent it
from working properly.
Unit will not operate without battery power. The Smoke Alarm
cannot work until you install the battery in the correct position
(Match “+” to “+” and “-” to “-”).
This Smoke Alar
m has a batter
y drawer which r
esists closing
unless a batter
y is installed.
Do not install this unit over an electrical junction box.
Air currents around junction boxes can prevent smoke from
reaching the sensing chamber and prevent the unit from
alarming. Only AC powered units are intended for installation
over junction boxes.
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn
at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit fr
om operating pr
operly
.
1 2 3
1. Mounting bracket
2. Mounting slots
3.
Battery drawer, install 9V
battery here
4.
Turn this way to remove
fr
om bracket
5.
Turn this way to attach
to bracket
1. Test/Silence button
2. Battery drawer
3.
Power indicator light and
alarm indicator
4. Escape
Light
®
If you want to lock the battery drawer, or lock the Smoke Alarm
to the mounting bracket, please r
ead the “Optional Locking
Featur
es” section before you begin installation.
1. Hold base firmly and twist the mounting bracket counterclockwise
to separate it fr
om the base.
2. Hold the mounting bracket against the ceiling (or wall) so the
vertical mounting slot is aligned in the 12 o’clock position and
trace ar
ound the inside of the mounting slots (vertical and
horizontal mounting).
3.
Put the unit where it won’t get covered with dust when you drill
the mounting holes.
4.
Using a 3/16” (5 mm) drill bit, drill a hole through the center of the
oval outlines you traced.
5.
Insert the plastic screw anchors (in the plastic bag with screws)
into the holes. T
ap the screw anchors gently with a hammer, if
necessary, until they are flush with the ceiling or wall.
6.
Attach the mounting bracket to the ceiling or wall.
7.
Install the battery (included). Open the
battery drawer
. Match the terminals on the
end of the battery with the terminals on the
unit. Match “+” to “+” and “-” to “-.” Push
the battery in until it snaps in secur
ely and
cannot be shaken loose. If the battery is
not snapped in completely, the unit cannot
receive battery power.
NOTE: After you install the battery, the power indicator light
may flash. (If the unit alar
ms, the light will blink rapidly, and the
horn will repeatedly sound 3 beeps, pause, 3 beeps.)
8. Attach the Smoke Alarm to the mounting bracket. Line up the
guides on the alarm’
s base with the guides on the mounting
bracket. When guides are lined up, turn the base clockwise (right)
until it snaps into place.
NOTE: Once the Smoke Alar
m is snapped onto the mounting
bracket, you can r
otate the Smoke Alarm to adjust the align-
ment.
9. Test the Smoke Alarm. See “Weekly Testing.”
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. The Escape Light
®
will tur
n on.
LED flashes once every second.
If the unit alarms get everyone out of the house immediately.
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignor
e any alarm. Ignoring the
alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke Alarm
to stop an unwanted alarm (caused by cooking smoke, etc.).
Removing batteries disables the alar
m so it cannot sense smoke,
and r
emoves your protection. Instead open a window or fan the
smoke away from the unit. The alarm will reset automatically.
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of dead, missing or
weak batteries, a build-up of dirt, dust or gr
ease on the Smoke Alarm
cover
, or installation in an improper location. Clean the Smoke Alarm as
described in “Regular Maintenance,” and install a fresh battery, then test
the Smoke Alarm again. If it fails to test pr
operly when you use the test
button, or if the pr
oblem persists, replace the Smoke Alarm immediately.
If you hear a “chirp” about once a minute, replace the battery.
If you experience frequent non-emergency alarms (like those
caused by cooking smoke), tr
y r
elocating the Smoke Alarm.
If the alar
m sounds when no smoke is visible, tr
y cleaning or
r
elocating the Smoke Alarm. The cover may be dirty.
If the alarm does not sound during testing, try installing a new
batter
y
, and make sur
e it is snapped in secur
ely
.
The Escape Light
®
bulb is not replaceable. In the unlikely event
that the Escape Light
®
does not operate during testing, please
obtain warranty service.
If the Smoke Alarm is still not operating pr
operly, and it is still under
warranty
, please see “How to Obtain W
arranty Service” in the Limited
Warranty.
Do not tr
y fixing the alarm yourself – this will void your warranty!
SMOKE AND FIRE* ALARM
LIMITED WARRANTY
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand pr
oducts
warrants that for a period of ten years from the date of purchase, this
pr
oduct will be free from defects in material and workmanship. BRK, at
its option, will r
epair or r
eplace this pr
oduct or any component of the
product found to be defective during the warranty period. Replacement
will be made with a new or r
emanufactured product or component.
If the pr
oduct is no longer available, r
eplacement may be made with a
similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial r
etail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or r
etail stores selling BRK products do
not have the right to alter
, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting
fr
om any of the following: negligent use or misuse of the pr
oduct, use on
improper voltage or current, use contrary to the operating instructions,
disassembly
, r
epair or alteration by anyone other than BRK or an
authorized service center. Further, the warranty does not cover Acts of
God, such as fire, flood, hurricanes and tornadoes or any batteries that
ar
e included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to
the extent prohibited by applicable law, any implied warranty of
mer
chantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty
. Some states, pr
ovinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary fr
om state to state or pr
ovince to pr
ovince.
How to Obtain Warranty Service
Ser
vice:
If service is r
equir
ed, do not return the product to your retailer.
In or
der to obtain warranty service, contact the Consumer Af
fairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday. To assist us in serving you, please have the
model number and date of pur
chase available when calling.
For W
ar
ranty Ser
vice r
eturn to:
25 Spur Drive, El Paso, TX 79906
Batter
y:
BRK Brands, Inc. make no warranty
, expr
ess or implied, written
or oral, including that of merchantability or fitness for any particular
purpose with respect to battery.
RECOMMENDED
LOCATIONS FOR
SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor
, in every sleeping ar
ea, and in every bed
-
room. In new construction, the Smoke Alarms must be AC powered and
inter
connected. See “Agency Placement Recommendations” for details.
For additional coverage, it is r
ecommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F
(38˚ C). Make sure no door or other obstruction could keep smoke from
reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping ar
ea. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters) long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for curr
ent r
equir
ements in your area.
It is r
ecommended AC or AC/DC
units be interconnected for added protection.
See “Recommended Locations For Smoke Alarms” diagram on the
following page.
INSTALLING SMOKE ALARMS IN MOBILE HOMES & RVS
For minimum security install one Smoke Alarm as close to each sleeping
ar
ea as possible. For more security, put one unit in each room. Many
older mobile homes (especially those built befor
e 1978) have little or no
insulation. If your mobile home is not well insulated, or if you are unsure
of the amount of insulation, it is important to install units on inside walls
only
. Smoke Alarms should be installed where temperatures normally
r
emain between 40˚ F (4˚ C) and 100˚ F (38˚ C).
W
ARNING: Test units
used in R
Vs after the vehicle has been in storage, before every trip,
and once a week while in use. Failur
e to test units used in RVs as
described may r
emove your protection.
This equipment should be installed in accor
dance with NFPA (National
Fir
e Protection Association) 72 and 101. National Fire Protection
Association, One Batterymarch Park, Quincy, MA 02269-9101.
Additional local building and r
egulatory codes may apply in your
ar
ea. Always check compliance requirements before beginning
any installation. This model is not RV listed with Underwriters
Laboratories Inc.
AGENCY PLACEMENT RECOMMENDA
TIONS
NFP
A 72 (National Fire Code)
Smoke Alarms shall be installed in each separate sleeping room, outside
each sleeping ar
ea in the immediate vicinity of the bedrooms and on
each additional story of the family living unit, including basements and
excluding crawl spaces and unfinished attics.
In new construction, Alarms shall be so arranged that operation of any
one Alarm shall cause the operation of all Alarms within the dwelling.
Smoke Detection-Ar
e More Smoke Alarms Desirable?
The r
equired
number of Smoke Alarms might not pr
ovide reliable early warning
pr
otection for those ar
eas separated by a door fr
om the ar
eas pr
otected
by the r
equired Smoke Alarms. For this reason, it is recommended that
the householder consider the use of additional Smoke Alarms for those
areas for increased protection. The additional areas include the base-
ment, bedr
ooms, dining room, furnace room, utility room, and hallways
not pr
otected by the r
equir
ed Smoke Alarms. The installation of Smoke
Alarms in kitchens, attics (finished or unfinished), or garages is not
normally r
ecommended, as these locations occasionally experience
conditions that can r
esult in improper operation.
Califor
nia State Fire Marshal (CSFM)
Early war
ning detection is best achieved by the installation of fir
e
detection equipment in all rooms and areas of the household as follows:
A Smoke Alarm installed in each separate sleeping ar
ea (in the vicinity
,
but outside bedr
ooms), and Heat or Smoke Alarms in the living r
ooms,
dining rooms, bedrooms, kitchens, hallways, finished attics, furnace
rooms, closets, utility and storage rooms, basements, and attached
garages.
LOCA
TIONS
TO AVOID FOR SMOKE ALARMS
For best per
for
mance, it is r
ecommended you AVOID installing
Smoke Alarms in these areas:
Where combustion particles are produced. Combustion particles
form when something bur
ns. Areas to avoid include poorly ventilated
kitchens, garages, and fur
nace rooms. Keep units at least 20 feet
(6 meters) fr
om the sour
ces of combustion particles (stove, fur
nace,
water heater
, space heater) if possible. In areas where a 20-foot
(6-meter) distance is not possible – in modular
, mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
placed as far fr
om these fuel-burning sources as possible. The
placement r
ecommendations ar
e intended to keep these Alarms at
a r
easonable distance from a fuel-burning source, and thus reduce
“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. Ventilate these
ar
eas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
In very damp, humid or steamy areas, or directly near bathrooms
with showers. Keep units at least 10 feet (3 meters) away fr
om
showers, saunas, dishwashers, etc.
Wher
e the temperatur
es ar
e regularly below 40˚ F (4˚C) or above
100˚ F (38˚C), including unheated buildings, outdoor rooms, porches,
or unfinished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
dir
ectly over the stove or range. Keep laundry r
oom Smoke Alarms
free of dust or lint.
Near fr
esh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the
sensing chamber
.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights.
Electrical “noise” can interfere with the sensor.
In “dead air” spaces. “Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
“Dead air” spaces may pr
event smoke fr
om r
eaching the Smoke Alarm.
T
o avoid dead air spaces, follow the installation recommendations
below.
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least 4
inches (102 mm) fr
om the wall or cor
ner
.
For wall mounting (if allowed by building codes), the top edge of
Smoke Alarms should be placed between 4 and 12 inches (102 and
305 mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally. Additional Smoke Alarms may be required depending on
the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
details on requirements for sloped or peaked ceilings.
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, long-
term health car
e facilities, nursing homes, day car
e facilities, or group
homes of any kind—even if they wer
e once single-family homes. It is
not a suitable substitute for complete fire detection systems in ware-
houses, industrial facilities, commer
cial buildings, and special-purpose
non-r
esidential buildings which require special fire detection and alarm
systems. Depending on the building codes in your area, this Smoke
Alarm may be used to pr
ovide additional pr
otection in these facilities.
The following infor
mation applies to all four building types below:
In new construction, most building codes r
equir
e the use of AC or
AC/DC powered Smoke Alarms only. In existing construction, AC,
AC/DC, or DC power
ed Smoke Alarms can be used as specified by
local building codes. Refer to NFP
A 101 (Life Safety Code) or NFP
A 72
(National Fire Alarm Code), local building codes, or consult your Fire
Department for detailed fir
e protection requirements in buildings not
defined as “households.”
1. Single-Family Residence:
Single family home, townhouse. It is r
ecommended Smoke Alarms be
installed on every level of the home, in every bedr
oom, and in each
bedr
oom hallway.
2. Multi-Family or Mixed Occupant Residence:
Apartment building, condominium. This Smoke Alarm is suitable for use
in individual apartments or condos, pr
ovided a primary fire detection
system alr
eady exists to meet fir
e detection requirements in common
ar
eas like lobbies, hallways, or por
ches. Using this Smoke Alarm in
common areas may not provide sufficient warning to all residents or
meet local fir
e protection ordinances/regulations.
3. Institutions:
Hospitals, day car
e facilities, long-term health care facilities. This
Smoke Alarm is suitable for use in individual patient sleeping/r
esident
r
ooms, provided a primary fire detection system already exists to meet
fir
e detection requirements in common areas like lobbies, hallways, or
por
ches. Using this Smoke Alarm in common ar
eas may not pr
ovide
suf
ficient warning to all residents or meet local fire protection ordinances
/r
egulations.
4. Hotels and Motels:
Also boar
ding houses and dormitories. This Smoke Alarm is suitable
for use inside individual sleeping/r
esident r
ooms, pr
ovided a primary
fir
e detection system already exists to meet fire detection requirements
in common areas like lobbies, hallways, or porches. Using this Smoke
Alarm in common areas may not provide sufficient warning to all
r
esidents or meet local fir
e pr
otection ordinances/regulations.
LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key r
ole in reducing deaths resulting from
home fires worldwide. However, like any warning device, Smoke Alarms
can only work if they ar
e properly located, installed, and maintained,
and if smoke r
eaches them. They are not foolproof.
Smoke alar
ms may not waken all individuals.
Practice the escape
plan at least twice a year, making sure that everyone is involved – from
kids to grandparents. Allow children to master fire escape planning and
practice befor
e holding a fir
e drill at night when they ar
e sleeping.
If children or others do not readily waken to the sound of the smoke
alarm, or if ther
e ar
e infants or family members with mobility limitations,
make sur
e that someone is assigned to assist them in fire drill and in
the event of an emer
gency
. It is recommended that you hold a fire drill
while family members ar
e sleeping in or
der to determine their r
esponse
to the sound of the smoke alarm while sleeping and to determine
whether they may need assistance in the event of an emergency.
Smoke Alarms cannot work without power. Battery operated units
cannot work if the batteries are missing, disconnected or dead, if the
wrong type of batteries are used, or if the batteries are not installed
corr
ectly
. AC units cannot work if the AC power is cut of
f for any r
eason
(open fuse or circuit breaker, failure along a power line or at a power
station, electrical fir
e that bur
ns the electrical wir
es, etc.). If you are
concerned about the limitations of battery or AC power, install both
types of units.
Smoke Alarms cannot detect fires if the smoke does not reach
them.
Smoke fr
om fires in chimneys or walls, on roofs, or on the other
side of closed doors may not r
each the sensing chamber and set of
f the
alarm. That is why one unit should be installed inside each bedroom or
sleeping area—especially if bedroom or sleeping area doors are closed
at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
home.
For example, a stand-alone unit on the second floor may not
detect smoke fr
om a basement fir
e until the fir
e spreads. This may not
give you enough time to escape safely. That is why recommended
minimum pr
otection is at least one unit in every sleeping ar
ea, and every
bedroom on every level of your home. Even with a unit on every floor,
stand-alone units may not provide as much protection as interconnected
units, especially if the fir
e starts in a r
emote ar
ea. Some safety experts
r
ecommend installing interconnected AC powered units with battery
back-up (see “About Smoke Alarms”) or professional fire detection
systems, so if one unit senses smoke, all units alarm. Interconnected
units may pr
ovide earlier warning than stand-alone units since all units
alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit
meets or exceeds curr
ent standar
ds, it may not be hear
d if: 1) the unit
is located outside a closed or partially closed door, 2) residents recently
consumed alcohol or drugs, 3) the alarm is dr
owned out by noise fr
om
stereo, TV, traffic, air conditioner or other appliances, 4) residents are
hearing impaired or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not reach the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions r
esulting fr
om escaping gas.
Smoke Alarms are not foolproof.
Like any electronic device, Smoke
Alarms ar
e made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot prevent or extinguish fires. They are not a
substitute for pr
operty or life insurance.
Smoke Alarms have a limited life. The unit should be replaced
immediately if it is not operating pr
operly
. Y
ou should always replace a
Smoke Alarm after 10 years from date of purchase. Write the purchase
date on the space provided on back of unit.
First Alert
®
is a r
egister
ed trademark of the First Alert Trust.
4 5
6
ABOUT
SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units ar
e easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with batter
y (DC) back-up:
will operate if electricity fails, pr
ovided
the batteries are fresh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
Smoke Alar
ms for Solar or Wind Energy users and battery backup
power systems:
AC powered Smoke Alarms should only be operated
with true or pur
e sine wave inverters. Operating this Smoke Alarm with
most battery-power
ed UPS (uninterruptible power supply) products or
square wave or “quasi sine wave” inverters
will damage the Alarm.
If you ar
e not sure about your inverter or UPS type, please consult with
the manufactur
er to verify.
Smoke Alar
ms for the hearing impaired:
Special purpose Smoke
Alarms should be installed for the hearing impair
ed. They include a
visual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be inter
connected so if one
unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and car
ed for as described in the user’s manual, and
if smoke r
eaches them. If you are unsure which type of Smoke Alarm
to install, refer to Chapter 2 of the National Fire Protection Association
(NFP
A) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life
Safety Code). National Fir
e Protection Association, One Batterymarch
Park, Quincy, MA 02269-9101. Local building codes may also require
specific units in new construction or in dif
ferent areas of the home.
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
F
INISHED BASEMENT
REQUIRED TO MEET
NFPA RECOMMENDATIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM
KITCHEN
L
IVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOB
ILE HOME
K
EY:
EXISTING HOMES
SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
A
DDITIONAL PROTECTION
BEDROOM
BEDROOM
HALL
L
IVING ROOM KITCHEN
FINISHED BASEMENT
BEDROOM
BEDROOM
L
IVING ROOM
D
INING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
EXISTING HOMES
K
ITCHEN
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RE
COMMENDED
F
OR ADDITIONAL
PROTECTION
K
EY:
SMOKE ALARMS WITH SILENCE
F
EATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED AC OR
AC/DC SMOKE ALARMS
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
F
INISHED BASEMENT
REQUIRED TO MEET
NFPA RECOMMENDATIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
B
EDROOM
BEDROOM
LI
VING ROOM
DININ
G ROOM
MULT I-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
KITC
HEN
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
B
EDROOM
B
EDROOM
HALL
LI
VING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM
LI
VING ROOM
DININ
G ROOM
MULT I-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEATURES
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KITCHEN
Printed in Mexico M08-0136-001 K1 08/07
RECOMMENDED
LOCATIONS FOR SMOKE ALARMS
WHA
T TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to get
dressed or collect anything.
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape thr
ough them.
Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sur
e everybody got out safely.
Call the Fire Department as soon as possible from outside.
Give your addr
ess, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alar
ms have various limitations. See "Limitations of Smoke Alarms"
for details.
USING THE SILENCE FEATURE
The Silence Feature can temporarily quiet an unwanted alarm for up to
15 minutes. T
o use this featur
e, press the “Push to Test/Silence” button
on the cover
.
If the unit will not silence and no heavy smoke is
present, or if it stays in silence mode continuously, it should be
r
eplaced immediately
. The LED will flash every 10 seconds while in
silence.
The Silence Feature does not disable the unit—it makes it temporarily
less sensitive to smoke. For your safety
, if smoke around the unit is
dense enough to suggest a potentially danger
ous situation, the unit
will stay in alarm or may re-alarm quickly. If you do not know the
sour
ce of the smoke, do not assume it is an unwanted alarm. Not
r
esponding to an alarm can result in property loss, injury, or death.
TOOLS YOU WILL NEED:
This unit is designed to be mounted
on the ceiling, or on the wall if necessary.
• Pencil
• Drill with 3/16” (5 mm) drill bit
Standard flathead screwdriver
• Hammer
Pliers to activate optional “tamper-resistant”
locking featur
es
TO LOCK THE BATTERY COMPARTMENT
Do not lock the batter
y compartment until you have installed the
battery and tested the unit.
1. Install the batter
y
so the terminals
on the battery match the terminals
on the Smoke Alarm. Match “+” to
“+” and “-” to “-.” Push the battery in
until it snaps in securely and cannot
be shaken loose. If the battery is
not snapped in completely
, the unit
cannot receive battery power.
2. Push and hold Test/Silence button
until the alarm sounds: 3 beeps,
pause, 3 beeps, pause.
The Escape Light
®
will turn on.
LED flashes once every second.
If the unit does not alar
m during
testing, DO NOT lock the batter
y
compartment! Install a new battery
and test again. If the Smoke Alar
m still
does not alar
m, r
eplace it immediately
.
3.
Using needle-nose pliers, detach
one locking pin from the mounting
bracket.
4. Push the locking pin through the
hole near the battery door latch on
the back of the Smoke Alarm.
OPTIONAL LOCKING FEATURES
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers,
detach one locking pin fr
om
the mounting bracket.
2.
Insert the locking pin thr
ough
the hole on the back of the
Smoke Alarm as shown in the
diagram.
3. When you attach the Smoke
Alarm to the mounting bracket,
the locking pin’
s head will fit
into a notch on the bracket.
The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in
single-family households wher
e unauthorized battery or alarm removal is not a concern.
These Smoke Alarms have two separate locking featur
es: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting
bracket. Y
ou can choose to use either feature independently, or use them both.
T
ools you will need: • Needle-nose pliers • Standard flathead screwdriver.
Both locking featur
es use locking pins, which are molded into the mounting bracket. Depending on which locking
features you use, remove one or both pins from the mounting bracket using needle-nose pliers.
T
o permanently remove either locking pin, insert a flathead screwdriver between the locking pin and the
lock, and pry the pin out of the lock.
TO UNLOCK THE BA
TTER
Y COMP
AR
TMENT
1.
Remove the Smoke Alarm
fr
om the mounting bracket.
If the unit is locked to the
bracket, see the section
“T
o Unlock the Mounting
Bracket.”
2.
Insert a flathead scr
ewdriver
under the head of the locking
pin, and gently pry it out of the
battery compartment lock.
(If you plan to r
elock the battery
compartment, save the locking
pin.)
3. To relock the battery compart-
ment, close the battery door
and r
einsert locking pin in lock.
4.
Reattach the Smoke Alarm
to the mounting bracket.
When r
eplacing the batter
y
, always
test the Smoke Alar
m before
relocking the battery compartment.
TO UNLOCK THE MOUNTING BRACKET
1.
Insert a flathead scr
ewdriver into
the r
ectangular cut-out on the
mounting bracket near
est to the
locking pin.
2. Pry the Smoke Alarm away from
the bracket by pushing up on
the scr
ewdriver and tur
ning the
Smoke Alarm counterclockwise
(left) at the same time.
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home.
The built-in test switch accurately tests the unit’
s operation as
required by Underwriters Laboratories, Inc. (UL).
If the Alar
m ever fails to test pr
operly
, r
eplace it immediately
.
Products under warranty may be returned to the manufacturer
for r
eplacement. See “Limited Warranty” for details.
DO NOT stand close to the alarm when the horn is sounding.
Exposur
e at close range may be harmful to your hearing. When
testing, step away when hor
n starts sounding.
It is impor
tant to test this unit ever
y week to make sure it is working
properly.
Using the Test/Silence button is the recommended way to
test this Smoke Alarm. Press and hold the Test/Silence button on the
cover of the unit until the alarm sounds and the
Escape Light
®
tur
ns on
(the unit may continue to alarm for a few seconds after you release the
button). If it does not alarm, make sure the unit is receiving power and
test it again. If it still does not alarm, r
eplace it immediately.
During testing you will hear a loud, repeating horn pattern: 3 beeps,
pause, 3 beeps, pause. The Escape Light
®
will turn on. LED flashes
once every second.
WEEKLY TESTING
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there are a few simple things you must do to keep it working properly.
Use only the r
eplacement batteries listed below. The unit may not
operate properly with other batteries. Never use rechargeable
batteries since they may not provide a constant charge.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum off
any dust using your household vacuum’s soft brush attachment,
and test the Smoke Alarm after cleaning. Never use water, cleaners
or solvents since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately.
Relocate the unit if it sounds fr
equent unwanted alarms.
See “Locations to Avoid For Smoke Alarms” for details.
When the battery becomes weak, the Smoke Alarm unit will “chirp”
approximately once a minute (the low battery warning). This low
battery warning should last for up to 30 days, but you should
replace the battery immediately to continue your protection.
Choosing a replacement battery:
Your Smoke Alarm requires one standard 9V battery. The following
batteries are acceptable as replacements: Duracell #MN1604, (Ultra)
#MX1604; Eveready (Energizer) #522. You may also use a Lithium
battery like the Ultralife U9VL-J for longer service life between battery
changes.
These batteries are available at many local retail stores.
Actual service life depends on the Smoke Alarm and the environment
in which it is installed. All the batteries specified above are acceptable
replacement batteries for this unit. Regardless of the manufacturer’s
suggested battery life, you MUST r
eplace the battery immediately once
the unit starts “chirping” (the “low battery war
ning”).
BATTERY POWERED PHOTOELECTRIC SMOKE ALARM
WITH SILENCE AND ESCAPE LIGHT
®
Model SA720