BRK electronic FCD3N Carbon Monoxide Alarm User Manual


 
CO Alarm goes back into alarm 4 minutes after you
pr
ess the T
est/Silence button.
CO levels indicate a potentially dangerous situation. IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EV
ACUA
TE your home and call 911 or
the Fire Department. If not, press the Test/Silence
button again and
keep ventilating your home.
Hor
n chirps and yellow service light blinks three
times every 30 seconds.
CO
Alarm needs to be replaced. CO Alarms under warranty should be returned to
manufactur
er for replacement. See “Limited
Warranty” for details.
PROBLEM...
THIS MEANS...
YOU SHOULD...
The BATTERY Light continues to flash GREEN and
the hor
n “chirps” every 30 seconds.
Low battery warning. Install a new 9V alkaline or lithium battery
*.
INSTALLATION
WHERE TO INSTALL CO ALARMS
The National Fir
e Protection Association (NFPA) recommends that a CO Alarm
should be centrally located outside of each separate sleeping ar
ea in the
immediate vicinity of the bedrooms. For added protection, install additional
CO Alarms in each separate bedr
oom, and on every level of your home.
If your bedr
oom hallway is longer than 40 feet 12 meters), install a CO Alarm
at BOTH ends of the hallway
.
In a Single-level Home:
Install at least one CO Alarm near or within each separate sleeping area.
For added protection, install an additional CO Alarm at least 20 feet
(6 meters) away fr
om the furnace or fuel burning heat source.
In a Multi-level Home:
Install at least one CO Alarm near or within each separate sleeping ar
ea.
For added protection, install at least one CO Alarm on each level of the
home. If you have a basement, install that CO Alarm at the top of the
basement stairs.
For added pr
otection, install an additional CO Alarm at least 20 feet
(6 meters) away fr
om the furnace or fuel burning heat source.
In a Mobile Home:
Install CO Alarms on inside walls ONLY. Uninsulated outside walls and
roofs of mobile homes often transfer heat and cold from outdoors.
WHERE CO ALARMS SHOULD NOT BE
INST
ALLED
DO NOT LOCATE THIS CO ALARM:
In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or
gr
easy areas.
Closer than 20 feet (6 meters) from a furnace or other fuel burning heat
sour
ce, or fuel burning appliances like a water heater.
Within 5 feet (1.5 meters) of any cooking appliance.
In extremely humid areas. This alarm should be at least 10 feet (3 meters)
fr
om a bath or shower
, sauna, humidifier
, vaporizer
, dishwasher, laundry
room, utility room or other source of high humidity.
In ar
eas wher
e temperatur
e is colder than 40˚ F (4˚ C) or hotter than 100˚F
(38˚ C). These areas include unconditioned crawl spaces, unfinished
attics, uninsulated or poorly insulated ceilings, por
ches, and garages.
In turbulent air, like near ceiling fans, heat vents, air conditioners,
fr
esh air r
eturns, or open windows. Blowing air may prevent CO from
reaching the sensors.
In dir
ect sunlight.
This CO Alar
m is designed for use inside a single-family home or apar
t
-
ment. It is not meant to be used in common lobbies, hallways, or base
-
ments of multi-family buildings unless working CO Alarms are also
installed in each family living unit. CO Alarms in common areas may not
be hear
d from inside individual family living units.
This CO Alarm alone is not a suitable substitute for complete detection
systems in places which house many people, like hotels or dormitories,
unless a CO Alarm is also placed in each unit.
DO NOT use this CO Alarm in warehouses, industrial or commercial
buildings, special-purpose non-r
esidential buildings, RVs, boats, or air-
planes. This CO Alarm is specifically designed for residential use, and
may not provide adequate protection in non-residential applications.
CO ALARM IS IN ALARM
Sensor has detected enough CO
to trigger an alarm. ALARM light
flashes RED rapidly and hor
n
sounds loudly. See “If Your CO
Alarm Sounds” for details.
USER’S MANUAL
BATTERY OPERATED CARBON MONOXIDE ALARM
WITH SILENCE FEATURE
Model FCD3N
Printed in Mexico
M08-0013-003
P 06/07
IMPOR
TANT!
PLEASE READ CAREFULLY AND SAVE.
This user’
s manual contains important information about your Carbon
Monoxide (CO) Alarm’
s operation. If you are installing this CO Alarm for use
by others, you must leave this manual—or a copy of it—with the end user.
TABLE OF CONTENTS
Intr
oduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How Y
our CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
What the Lights and Alarm T
ones Mean
. . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Wher
e to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2
How to Install Y
our CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Featur
e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
T
esting and Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
W
eekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regular Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What Y
ou Need T
o Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6
What is CO?
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Symptoms of CO Poisoning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Finding the Sour
ce of CO After an Alarm . . . . . . . . . . . . . . . . . . . . . . .4
How Can I Pr
otect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Potential Sour
ces of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . .5-6
Under
writers Laboratories Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
General Limitations of CO Alar
ms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
T
r
oubleshooting Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6
Limited W
ar
ranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
© 2007 BRK Brands, Inc., a Jar
den Corporation company (NYSE: JAH)
3901 Liberty Str
eet Road, Aurora, IL 60504-8122
All rights reserved.
Consumer Affairs: (800) 323-9005
www
.brkelectr
onics.com
www
.firstalert.com
INTRODUCTION
BASIC SAFETY INFORMATION
Dangers, Warnings, and Cautions alert you to important operating
instructions or to potentially hazardous situations. Pay special
attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect
carbon monoxide fr
om ANY source of combustion. It is NOT designed
to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences.
It is NOT designed for marine use.
This CO Alar
m will only indicate the pr
esence of carbon monoxide gas
at the sensor
. Carbon monoxide gas may be present in other areas.
The Silence Featur
e is for your convenience only and will not cor
rect
a CO pr
oblem. Always check your home for a potential problem after
any alar
m. Failur
e to do so can result in injury or death.
NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to
“If Y
our CO Alarm Sounds” for more information. Failure to do so
can r
esult in injury or death.
T
est the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not
working properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of family
living units. It is not designed to measur
e CO levels in compliance
with Occupational Safety and Health Administration (OSHA)
commercial or industrial standards. Individuals with medical
conditions that may make them mor
e sensitive to carbon monoxide
may consider using warning devices which provide audible and
visual signals for carbon monoxide concentrations under 30 ppm.
For additional information on carbon monoxide and your medical
condition contact your physician.
HOW YOUR CO ALARM WORKS
GENERAL INFORMATION
This Co Alar
m does not operate without a working batter
y. Removing
the battery, or failure to replace it at the end of its service life,
removes your protection.
A CO Alarm measur
es the CO levels in the air. It will alarm if CO levels rise
quickly (if the heat exchanger on your furnace breaks, for example), or if CO
is consistently present (a slow CO leak on a fuel-burning appliance).
This carbon monoxide alarm features a permanently installed sensor, three
colored indicator lights, and an 85dB alarm horn. It also has a silence feature
to temporarily quiet the alarm horn.
THE COVER OF YOUR CO ALARM
1 2 3 4 5
LIMITED WARRANTY
BRK Brands, Inc. ("BRK") the maker of BRK
®
brand and First Alert
®
brand products, warrants that for a period of five years from the date of purchase, this product
will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may
be made with a similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original r
etail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase
is r
equir
ed to obtain warranty performance. BRK dealers, service centers, or r
etail stor
es selling BRK products do not have the right to alter, modify or any way
change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper
voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center.
Further, the warranty does not cover acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by
applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states,
provinces, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so
the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to
state, or province to province.
How to Obtain Warranty Service
Service:
If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at
1-800-323-9005, 7:30 AM to 5:00 PM, Central Standar
d Time, Monday thr
ough Friday
. T
o assist in serving you, please have the model number and date
of purchase available when calling.
For W
arranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. makes no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose, with
respect to battery.
6
WHAT THE LIGHTS AND ALARM TONES MEAN
LOW BATTERY WARNING
The BA
TTERY light continues to
flash GREEN and the horn “chirps”
every 30 seconds. This war
ning
should last for up to 30 days, but
you should replace the battery as
soon as possible.
WELCOME
CHIRP
Horn chirps and battery light blinks
gr
een once when battery is first
connected.
ALARM RECEIVING
BA
TTERY POWER
BATTERY light flashes GREEN
every 30 seconds. Hor
n is silent.
CO ALARM REQUIRES SER
VICE
The SERVICE light flashes YELLOW
and the horn sounds 3 quick
“chirps” every 30 seconds. CO
Alarm needs to be replaced.
GARAGE
SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS
BEDROOM
BEDROOM
HALL
LIVING ROOM
KITCHEN
BASEMENT
BEDROOM
REQUIRED TO MEET NFPA RECOMMENDATIONS
HOW TO INSTALL YOUR CO ALARM
Read “Wher
e To Install Your CO Alarm” before starting.
This CO Alarm
can be used on a tabletop or mounted on the wall. For tabletop use, choose
a table no taller than 36” (92 cm); a fall from a high table could damage the
CO Alarm’
s sensitive components.
Before you start installation, find the pair of self-adhesive labels included
with this CO Alarm. On each label write in the phone number of your emer-
gency r
esponder (like 911) and a qualified appliance technician. Place one
label near the CO Alarm, and the other label in the “fresh air” location you
plan to go if the alarm sounds.
NOTE: A qualified appliance technician is defined as “a person, firm,
corporation, or company that either in person or through a representative,
is engaged in and r
esponsible for the installation, testing, servicing, or
replacement of heating, ventilation, air conditioning (HVAC) equipment,
combustion appliances and equipment, and/or gas fireplaces or other
decorative combustion equipment.”
INSTALLING THE 9V BATTERY
1.
Slide the mounting bracket/battery door off the back of the CO Alarm.
2.
Attach the 9V battery (included) to the battery connector inside the
battery compartment. Make sur
e the battery snaps in securely, and
cannot be shaken loose.
3.
Place the battery and connector back inside the battery compartment.
For your safety, the CO Alarm will not close until a 9V battery is installed.
FOR TABLETOP USE
1. Close the battery compartment by sliding the
mounting bracket/battery door back onto the
back of the CO Alarm.
2.
Test the CO Alarm as described below.
3. Set the CO Alarm in plain view on a table where
it will not be blocked by any obstructions.T
able
height should not exceed 36” (92 cm).Put the CO
Alarm where children and pets cannot reach it.
IF YOUR CO ALARM SOUNDS
Actuation of your CO Alar
m indicates the pr
esence of carbon monoxide
(CO) which can kill you. In other words, when your CO Alarm sounds,
you must not ignor
e it!
IF THE ALARM SIGNAL SOUNDS:
1. Operate the Test/Silence button.
2.
Call your emergency services, fire department or 911. Write down the
number of your local emergency service here:
_________________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or window.
Do a head count to check that all persons ar
e accounted for. Do not re-
enter the pr
emises, or move away fr
om the open door or window until the
emer
gency services responder has arrived, the premises have been aired
out, and your CO Alarm r
emains in its normal condition.
4.
After following steps 1-3, if your CO Alarm reactivates within a 24-hour
period, repeat steps 1-3 and call a qualified appliance technician to inves-
tigate for sources of CO from fuel-burning equipment and appliances, and
inspect for pr
oper operation of this equipment. If pr
oblems ar
e identified
during this inspection have the equipment serviced immediately. Note
any combustion equipment not inspected by the technician, and consult
the manufacturers’ instructions, or contact the manufacturers directly, for
more information about CO safety and this equipment. Make sure that
motor vehicles ar
e not, and have not, been operating in an attached
garage or adjacent to the residence. Write down the number of a qualified
appliance technician here:
_________________________________________________________________
Alarms have various limitations. See "General Limitations of CO Alarms"
for details.
USING THE SILENCE FEA
TURE
The Silence Feature is for your convenience only and will not correct a
CO problem. Always check your home for a potential problem after any
alar
m. Failur
e to do so can r
esult in injur
y or death.
NEVER remove the batteries from your CO Alarm to silence the horn.
Use the silence feature. Removing the batteries removes your protection!
See “If Y
our CO Alar
m Sounds” for details on r
esponding to an alar
m.
The Silence Feature is intended to temporarily silence your CO Alarm’s alarm
hor
n while you corr
ect the pr
oblem—it will not corr
ect a CO pr
oblem. While
the alarm is silenced it will continue to monitor the air for CO.
When CO r
eaches alarm levels the alarm will sound— r
epeating hor
n patter
n:
4 beeps, a pause, 4 beeps, etc. Press and hold the Test/Silence button until
the hor
n is silent. The initial Silence cycle will last appr
oximately 4 minutes.
NOTE: After initial 4-minute Silence cycle, the CO Alarm re-evaluates present
CO levels and r
esponds accor
dingly. If CO levels remain potentially danger-
ous—or start rising higher—the hor
n will start sounding again.
While the detector is silenced:
If the CO Alarm...
Is silent for only 4 minutes, then
starts sounding loudly—4 beeps,
pause, 4 beeps, pause
This means...
CO levels are still potentially
dangerous.
If the CO Alarm...
Remains silent after your pressed
the Test/Silence button
This means...
CO levels are dropping.
WHAT YOU NEED TO KNOW ABOUT CO
WHA
T IS CO?
CO is an invisible, odorless, tasteless gas pr
oduced when fossil fuels do not
bur
n completely, or are exposed to heat (usually fire). Electrical appliances
typically do not pr
oduce CO.
These fuels include: W
ood, coal, charcoal, oil, natural gas, gasoline,
ker
osene, and pr
opane.
Common appliances ar
e often sources of CO. If they are not properly main-
tained, ar
e impr
operly ventilated, or malfunction, CO levels can rise quickly
.
CO is a real danger now that homes are more energy efficient. “Air-tight”
homes with added insulation, sealed windows, and other weatherpr
oofing
can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed
with ALL household members.
Mild Exposure:
Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).
Medium Exposur
e:
Throbbing headache, drowsiness, confusion, fast heart rate.
Extr
eme Exposure:
Convulsions, unconsciousness, heart and lung failure. Exposure to carbon
monoxide can cause brain damage, death.
Some individuals are more sensitive to CO than others, including people
with cardiac or respiratory problems, infants, unborn babies, pregnant
mothers, or elderly people can be mor
e quickly and sever
ely af
fected by
CO. Members of sensitive populations should consult their doctors for
advice on taking additional pr
ecautions.
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it dif
ficult
to locate the source of CO after an alarm. These are a few of the factors that
can make it difficult to locate sources of CO:
House well ventilated before the investigator arrives.
Problem caused by “backdrafting.”
Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be dif
fi-
cult to locate the sour
ce of CO.
BRK Brands, Inc. shall not be obligated to
pay for any carbon monoxide investigation or service call.
HOW CAN I PROTECT MY F
AMIL
Y?
A CO Alarm is an excellent means of pr
otection. It monitors the air and
sounds a loud alarm before carbon monoxide levels become threatening for
average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home appliances.
T
o help pr
event CO pr
oblems and r
educe the risk of CO poisoning:
Clean chimneys and flues yearly. Keep them free of debris, leaves, and
nests for pr
oper air flow
. Also, have a pr
ofessional check for rust and
corrosion, cracks, or separations. These conditions can prevent proper
air movement and cause backdrafting. Never “cap” or cover a chimney
in any way that would block air flow.
Test and maintain all fuel-burning equipment annually. Many local gas or
oil companies and HVAC companies offer appliance inspections for a
nominal fee.
Make regular visual inspections of all fuel-burning appliances. Check appli-
ances for excessive rust and scaling. Also check the flame on the burner
and pilot lights. The flame should be blue. A yellow flame means fuel is not
being burned completely and CO may be present. Keep the blower door
on the furnace closed. Use vents or fans when they are available on all
fuel-bur
ning appliances. Make sure appliances are vented to the outside.
Do not grill or barbecue indoors, or in garages or on scr
een por
ches.
Check for exhaust backflow from CO sources. Check the draft hood
on an operating fur
nace for a backdraft. Look for cracks on fur
nace
heat exchangers.
Check the house or garage on the other side of shar
ed wall.
Keep windows and doors open slightly. If you suspect that CO is escaping
into your home, open a window or a door
. Opening windows and doors
can significantly decrease CO levels.
In addition, familiarize yourself with all enclosed materials. Read this
manual in its entirety, and make sure you understand what to do if your
CO Alarm sounds.
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms to sound when exposed to levels of CO and exposur
e times as
described below
. They are measured in parts per million (ppm) of CO over
time (in minutes).
UL2034 Requir
ed Alarm Points*:
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN
4 and 15 MINUTES.
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN
10 and 50 MINUTES.
If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN
60 and 240 MINUTES.
* Appr
oximately 10% COHb exposure at levels of 10% to 95% Relative
Humidity (RH).
The unit is designed not to alarm when exposed to a constant level
of 30 ppm for 30 days.
CO Alarms ar
e designed to alarm before there is an immediate life threat.
Since you cannot see or smell CO, never assume it’
s not pr
esent.
An exposure to 100 ppm of CO for 20 minutes may not affect average,
healthy adults, but after 4 hours the same level may cause headaches.
An exposure to 400 ppm of CO may cause headaches in average, healthy
adults after 35 minutes, but can cause death after 2 hours.
This CO Alarm measur
es exposure to CO over time. It alarms if CO levels
are extremely high in a short period of time, or if CO levels reach a certain
minimum over a long period of time. The CO Alarm generally sounds an
alarm befor
e the onset of symptoms in average, healthy adults.
Why is this important? Because you need to be war
ned of a potential CO
problem while you can still react in time. In many reported cases of CO
exposur
e, victims may be aware that they are not feeling well, but become
disoriented and can no longer r
eact well enough to exit the building or get
help. Also, young children and pets may be the first affected. The average
healthy adult might not feel any symptoms when the CO Alarm sounds.
However, people with cardiac or respiratory problems, infants, unborn babies,
pregnant mothers, or elderly people can be more quickly and severely affected
by CO.If you experience even mild symptoms of CO poisoning, consult your
doctor immediately!
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon
monoxide alarms UL2034.
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon
monoxide alarms cover
ed by these requirements are intended to respond to
the pr
esence of carbon monoxide from sources such as, but not limited to,
exhaust from internal-combustion engines, abnormal operation of fuel-fired
appliances, and fir
eplaces. CO Alarms are intended to alarm at carbon
monoxide levels below those that could cause a loss of ability to r
eact to the
dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at
the Alarm, and is designed to alarm befor
e CO levels become life threatening.
This allows you pr
ecious time to leave the house and correct the problem.
This is only possible if Alarms are located, installed, and maintained as
described in this manual.
Gas Detection at T
ypical Temperature and Humidity Ranges:
The CO
Alarm is not formulated to detect CO levels below 30 ppm typically
. UL tested
for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane
(500 ppm), Ethyl Acetate (200 ppm), Isopr
opyl Alcohol (200 ppm) and Carbon
Dioxide (5000 ppm). V
alues measur
e gas and vapor concentrations in parts
per million.
Audible Alar
m:
85dB minimum at 10 feet (3 meters).
TESTING & MAINTENANCE
WEEKLY TESTING
Test the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not work-
ing pr
operly, it cannot alert you to a problem.
DO NOT stand close to the Alarm when the horn is sounding.
Exposur
e at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
Push and hold the T
est/Silence button on the cover until you hear a “chirp.”
The “chirp”marks the start of the self-test sequence.
First, the BATTERY (green) and SERVICE (yellow) lights will flash briefly—
this is normal.
Next, the alarm horn will sound: 4 beeps, a pause, then 4 beeps. The
ALARM (r
ed) light will flash quickly.
The alarm sequence should last 5-6 seconds. If it does not alarm, make sur
e
a fr
esh battery is correctly installed, and test it again. If the unit still does not
alarm, replace it immediately.
If the alar
m does not test properly:
1.
Make sure a fresh battery is installed correctly.
2. Be sure the Alarm is clean and dust-free.
3.
Install a fresh 9V alkaline or lithium battery
* and test the alarm again.
DO NOT tr
y fixing the Alarm yourself – this will void your warranty!
If the CO Alarm is still not operating properly, and it is still under
warranty, please see "How to Obtain Warranty Service" in the Limited
W
arranty. Install a new CO Alarm immediately.
The T
est/Silence button is the only proper way to test the CO Alarm.
NEVER use vehicle exhaust! Exhaust may cause per
manent damage
and voids your war
ranty.
*
For a list of acceptable r
eplacement batteries, see “Regular Maintenance.”
REGULAR MAINTENANCE
T
o keep the CO Alarm in good working order:
Test it every week using the Test/Silence button.
V
acuum the CO Alarm cover once a month, using the soft brush attach-
ment. Never use water, cleaners, or solvents, since these may damage the
unit. T
est the CO Alarm again after vacuuming.
Replace the battery when the CO Alarm “chirps” twice a minute (the low
battery war
ning).
The low battery war
ning should last for 30 days, but you should replace the
battery immediately to continue your pr
otection.
Choosing a r
eplacement battery:
This CO
Alarm requires one standard 9V alkaline battery. The following alka-
line batteries are acceptable as replacements: Duracell #MN1604 or MX1604;
Ever
eady “Ener
gizer” 522. You can also use an Ultralife 9 volt lithium battery
#U9VL for longer service life between battery changes. These r
eplacement
batteries ar
e commonly available at local r
etail stor
es.
Use only the alkaline or lithium r
eplacement batteries listed. The unit may not
operate properly with other batteries. Never use rechargeable batteries since
they may not pr
ovide a constant charge.
DO NOT spray cleaning chemicals or insect sprays dir
ectly on or near
the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause
per
manent damage.
Household cleaners, aer
osol chemicals, and other contaminants can af
fect the
sensor
. When using any of these materials near the CO Alarm, make sure the
r
oom is well ventilated.
This CO Alar
m is intended for residential use. It is not intended for
use in industrial applications where Occupational Safety and Health
Administration (OSHA) r
equirements for carbon monoxide detectors
must be met.
CO alar
ms may not waken all individuals.
If childr
en or others do not readily
waken to the sound of the CO alarm, or if there are infants or family members
with mobility limitations, make sur
e that someone is assigned to assist them in
the event of an emer
gency
.
CO Alar
ms will not work without power.
This alarm r
equires a 9V alkaline or
lithium battery to operate.
CO Alarms for Solar or Wind Energy users and battery backup power
systems:
AC power
ed CO Alarms should only be operated with true or pur
e
sine wave inverters. Operating this Alarm with most battery-power
ed UPS
(uninterruptible power supply) products or square wave or “quasi sine wave”
inverters
will damage the Alar
m
. If you ar
e not sur
e about your inverter or
UPS type, please consult with the manufactur
er to verify.
This CO Alar
m will not sense carbon monoxide that does not r
each the
sensor. This CO Alarm will only sense CO at the sensor. CO may be present
in other ar
eas. Doors or other obstructions may affect the rate at which CO
r
eaches the CO Alarm. For this reason, if bedroom doors are usually closed
at night, we recommend you install a CO Alarm in each bedroom and in the
hallway between them.
CO Alar
ms may not sense CO on another level of the home.
For example,
a CO Alarm on the second level, near the bedr
ooms, may not sense CO in the
basement. For this r
eason, one CO Alarm may not give adequate warning.
Complete coverage is r
ecommended. Place CO Alarms on each level of the home.
CO Alar
ms may not be heard.
The alarm hor
n loudness meets or exceeds
current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm
is installed outside the bedr
oom, it may not wake up a sound sleeper or one
who has r
ecently used drugs or has been drinking alcoholic beverages. This
is especially true if the door is closed or only partly open. Even persons who
ar
e awake may not hear the alarm hor
n if the sound is blocked by distance or
closed doors. Noise fr
om traffic, stereo, radio, television, air conditioner, or
other appliances may also prevent alert persons from hearing the alarm horn.
This CO Alarm is not intended for people who ar
e hearing impair
ed.
CO Alar
ms are not a substitute for a smoke alarm.
Although fir
e is a source
of carbon monoxide, this CO Alarm does not sense smoke or fir
e. This CO
Alarm senses CO that may be escaping unnoticed from malfunctioning
fur
naces, appliances, or other sources. Early warning of fire requires the
installation of smoke alarms.
CO Alar
ms are not a substitute for life insurance.
Though these CO Alarms
warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply
in any way that they will pr
otect lives from CO poisoning. Homeowners and
renters must still insure their lives.
CO Alar
ms have a limited life.
Although the CO Alarm and all of its parts
have passed many stringent tests and are designed to be as reliable as
possible, any of these parts could fail at any time. Ther
efor
e, you must test
your CO Alarm weekly
.
CO Alar
ms ar
e not foolproof.
Like all other electr
onic devices, CO Alarms
have limitations. They can only detect CO that reaches their sensors. They
may not give early war
ning to rising CO levels if the CO is coming from a
r
emote part of the home, away fr
om the CO Alarm.
TROUBLESHOOTING GUIDE
CO Alarm sounds frequently even though no high
levels of CO ar
e revealed in an investigation.
The CO Alarm may be improperly located. Refer to
“Wher
e to Install CO Alarms.”
Relocate your alarm. If frequent alarms continue,
have home r
echecked for potential CO problems.
Y
ou may be experiencing an intermittent CO pr
oblem.
If you have any questions that cannot be answer
ed by reading this manual, call Consumer Affairs at 1-800-323-9005.
1 Test/Silence Button
2 BATTERY Light (Green)
3 SERVICE Light (Yellow)
4 ALARM Light (Red)
5 (Behind Cover) Alarm Horn:
85dB audible alarm for test,
alarm, and unit malfunction
warning.
“ALARM-MOVE TO FRESH AIR”
During an alarm, move everyone
to a source of fresh air. DO NOT
move the CO Alarm!
TO TEST THIS CO ALARM:
Push and hold the T
est/Silence button on the cover until you hear
a “chirp.” The “chirp” marks the start of the self-test sequence.
First, the yellow and green lights will flash briefly—this is normal.
Next, the alarm horn will sound: 4 beeps, a pause, then 4 beeps.
The red light will flash quickly.
The alarm sequence should last 5-6 seconds. If it does not alarm, make
sur
e a fresh battery is correctly installed, and test it again. If the unit still
does not alarm, r
eplace it immediately.
TO MOUNT ON THE WALL
Tools you will need: pencil, drill with 3/16” or 5mm drill bit, flathead
scr
ewdriver
, hammer
.
1.
Choose a location on the wall. Do not install
the Alarm closer than 4” fr
om where the
wall meets the ceiling.
2. Hold the mounting bracket against the wall,
and make a mark inside each keyhole
wher
e you will drill your mounting hole.
3.
Use a 3/16” drill bit to drill through the
marks you made for the mounting holes.
4.
Insert the plastic scr
ew anchors into the mounting holes until they ar
e
flush with the wall. If necessary
, tap them gently with a hammer.
5.
Line up the mounting bracket up with the
scr
ew anchors, and scr
ew the bracket onto
the wall.
6.
Slide the CO Alarm onto the mounting
bracket until you feel it click into place.
7. Test the CO Alarm as described in “To Test
this CO Alarm.”
“ALARM-MOVE TO FRESH AIR”
If you hear the alar
m horn and the red light is flashing,
move ever
yone to a sour
ce of fresh air.
DO NOT disconnect the battery from the CO Alarm!
Fuel-burning appliances like: portable heater, gas or wood burning fireplace,
gas kitchen range or cooktop, gas clothes dryer
.
Damaged or insuf
ficient venting:
corr
oded or disconnected water heater
vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked
or clogged chimney opening.
Improper use of appliance/device: operating a barbecue grill or vehicle in
an enclosed area (like a garage or screened porch).
T
ransient CO Problems:
“transient” or on-again-of
f-again CO problems can
be caused by outdoor conditions and other special circumstances.
*For a list of acceptable r
eplacement batteries, see “Page 4: Regular Maintenance.”
GENERAL LIMITATIONS OF CO ALARMS
The following conditions can result in transient CO situations:
1.
Excessive spillage or reverse venting of fuel appliances caused by outdoor
conditions such as:
Wind direction and/or velocity, including high, gusty winds. Heavy air in
the vent pipes (cold/humid air with extended periods between cycles).
Negative pressure differential resulting from the use of exhaust fans.
• Several appliances running at the same time competing for limited
fr
esh air.
Vent pipe connections vibrating loose from clothes dryers, furnaces, or
water heaters.
Obstructions in or unconventional vent pipe designs which can amplify
the above situations.
2.
Extended operation of unvented fuel burning devices (range, oven,
fir
eplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4.
Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your
home. Since these conditions can come and go, they ar
e also hard to recreate
during a CO investigation.
POTENTIAL SOURCES OF CO IN THE HOME
UNDERWRITERS LABORATORIES INC. UL2034
For your r
ecor
ds, please record:
Date Purchased: ________________________________
Where Purchased: _________________________________________
BRK
®
is a registered trademark of BRK Brands, Inc.
First Alert
®
is a registered trademark of the First Alert Trust.
Printed in Mexico M08-0013-003 P 06/07
CONFORMS
TO UL 2034
ST
ANDARD